Commit f840ab18 authored by Lukasz Luba's avatar Lukasz Luba Committed by Zhang Rui

thermal: cpu_cooling: fix improper order during initialization

The freq_table array is not populated before calling
thermal_of_cooling_register. The code which populates the freq table was
introduced in commit f6859014.
This should be done before registering new thermal cooling device.
The log shows effects of this wrong decision.
[    2.172614] cpu cpu1: Failed to get voltage for frequency 1984518656000: -34
[    2.220863] cpu cpu0: Failed to get voltage for frequency 1984524416000: -34

Cc: <stable@vger.kernel.org> # 3.19+
Fixes: f6859014 ("thermal: cpu_cooling: Store frequencies in descending order")
Signed-off-by: default avatarLukasz Luba <lukasz.luba@arm.com>
Acked-by: default avatarJavi Merino <javi.merino@arm.com>
Acked-by: default avatarViresh Kumar <viresh.kumar@linaro.org>
Signed-off-by: default avatarZhang Rui <rui.zhang@intel.com>
parent 852f42a6
......@@ -857,14 +857,6 @@ __cpufreq_cooling_register(struct device_node *np,
goto free_power_table;
}
snprintf(dev_name, sizeof(dev_name), "thermal-cpufreq-%d",
cpufreq_dev->id);
cool_dev = thermal_of_cooling_device_register(np, dev_name, cpufreq_dev,
&cpufreq_cooling_ops);
if (IS_ERR(cool_dev))
goto remove_idr;
/* Fill freq-table in descending order of frequencies */
for (i = 0, freq = -1; i <= cpufreq_dev->max_level; i++) {
freq = find_next_max(table, freq);
......@@ -877,6 +869,14 @@ __cpufreq_cooling_register(struct device_node *np,
pr_debug("%s: freq:%u KHz\n", __func__, freq);
}
snprintf(dev_name, sizeof(dev_name), "thermal-cpufreq-%d",
cpufreq_dev->id);
cool_dev = thermal_of_cooling_device_register(np, dev_name, cpufreq_dev,
&cpufreq_cooling_ops);
if (IS_ERR(cool_dev))
goto remove_idr;
cpufreq_dev->clipped_freq = cpufreq_dev->freq_table[0];
cpufreq_dev->cool_dev = cool_dev;
......