Commit fd65ee5f authored by Chanwoo Choi's avatar Chanwoo Choi Committed by Anton Vorontsov

charger-manager: Use replacement variable to check state of battery

This patch remove unnecessary variable(cm->fullbatt_vchk_uV) by using
'desc->fullbatt_uV' field directly in fullbatt_handler() function
to check the state of battery.
Signed-off-by: default avatarChanwoo Choi <cw00.choi@samsung.com>
Signed-off-by: default avatarMyungjoo Ham <myungjoo.ham@samsung.com>
Signed-off-by: default avatarKyungmin Park <kyungmin.park@samsung.com>
Signed-off-by: default avatarAnton Vorontsov <anton.vorontsov@linaro.org>
parent dbb61fc7
......@@ -415,7 +415,7 @@ static void fullbatt_vchk(struct work_struct *work)
return;
}
diff = cm->fullbatt_vchk_uV;
diff = desc->fullbatt_uV;
diff -= batt_uV;
dev_dbg(cm->dev, "VBATT dropped %duV after full-batt.\n", diff);
......
......@@ -194,8 +194,6 @@ struct charger_desc {
* @charger_enabled: the state of charger
* @fullbatt_vchk_jiffies_at:
* jiffies at the time full battery check will occur.
* @fullbatt_vchk_uV: voltage in microvolt
* criteria for full battery
* @fullbatt_vchk_work: work queue for full battery check
* @emergency_stop:
* When setting true, stop charging
......@@ -218,7 +216,6 @@ struct charger_manager {
bool charger_enabled;
unsigned long fullbatt_vchk_jiffies_at;
unsigned int fullbatt_vchk_uV;
struct delayed_work fullbatt_vchk_work;
int emergency_stop;
......
Markdown is supported
0%
or
You are about to add 0 people to the discussion. Proceed with caution.
Finish editing this message first!
Please register or to comment