Vasil Dimov authored
This is a followup to the fix of Bug#51920 Innodb connections in row lock wait ignore KILL until lock wait timeout in that fix (rb://279) the behavior was changed to honor when a trx is interrupted during lock wait, but the returned error code was still "lock wait timeout" when it should be "interrupted". This change fixes the non-deterministically failing test binlog.binlog_killed, that failed like this: binlog.binlog_killed 'stmt' [ fail ] Test ended at 2010-05-12 11:39:08 CURRENT_TEST: binlog.binlog_killed mysqltest: At line 208: query 'reap' failed with wrong errno 1205: 'Lock wait timeout exceeded; try restarting transaction', instead of 0... Approved by: Sunny Bains (rb://344)
c88f2f61