- 03 Feb, 2010 2 commits
-
-
Kent Boortz authored
-
Luis Soares authored
-
- 02 Feb, 2010 2 commits
-
-
Kent Boortz authored
path names than 99 characters, using the USTAR format of the resulting source TAR. To be able to specify the use of USTAR when creating the source TAR, we needed both to update the GNU autotools version requirements slightly, and update the initiation of the tools to use more modern constructs.
-
Luis Soares authored
The test case rpl_binlog_corruption fails on windows because when adding a line to the binary log index file it gets terminated with a CR+LF (which btw, is the normal case in windows, but not on Unixes - LF). This causes mismatch between the relay log names, causing mysqld to report that it cannot find the log file. We fix this by creating the instrumented index file through mysql, ie, using SELECT ... INTO DUMPFILE ..., as opposed on relying on ultimatly OS commands like: -- echo "..." > index. These changes go into the file and make the procedure platform independent: include/setup_fake_relay_log.inc Side note: when using SELECT ... INTO DUMPFILE ..., one needs to check if mysqld is running with secure_file_priv. If it is, we do it in two steps: 1. create the file on the allowed location; 2. move it to the datadir. If it is not, then we just create the file directly on the datadir (so previous step 2. is not needed).
-
- 01 Feb, 2010 3 commits
-
-
Georgi Kodinov authored
resulution of bug #46895.
-
Georgi Kodinov authored
-
Georgi Kodinov authored
-
- 30 Jan, 2010 1 commit
-
-
unknown authored
REVOKE/GRANT; ALTER EVENT. The following statements support the CURRENT_USER() where a user is needed. DROP USER RENAME USER CURRENT_USER() ... GRANT ... TO CURRENT_USER() REVOKE ... FROM CURRENT_USER() ALTER DEFINER = CURRENT_USER() EVENT but, When these statements are binlogged, CURRENT_USER() just is binlogged as 'CURRENT_USER()', it is not expanded to the real user name. When slave executes the log event, 'CURRENT_USER()' is expand to the user of slave SQL thread, but SQL thread's user name always NULL. This breaks the replication. After this patch, All above statements are rewritten when they are binlogged. The CURRENT_USER() is expanded to the real user's name and host.
-
- 29 Jan, 2010 3 commits
-
-
Georgi Kodinov authored
-
Georgi Kodinov authored
Updated the certs to expire on 2015. Made sure they work with both yassl and openssl.
-
Ramil Kalimullin authored
column is used for ORDER BY Problem: filesort isn't meant for null length sort data (e.g. char(0)), that leads to a server crash. Fix: disregard sort order if sort data record length is 0 (nothing to sort). mysql-test/r/select.result: Fix for bug#49897: crash in ptr_compare when char(0) NOT NULL column is used for ORDER BY - test result. mysql-test/t/select.test: Fix for bug#49897: crash in ptr_compare when char(0) NOT NULL column is used for ORDER BY - test case. sql/filesort.cc: Fix for bug#49897: crash in ptr_compare when char(0) NOT NULL column is used for ORDER BY - assert added as filesort cannot handle null length sort data. sql/sql_select.cc: Fix for bug#49897: crash in ptr_compare when char(0) NOT NULL column is used for ORDER BY - don't sort null length data e.g. in case of ORDER BY CHAR(0).
-
- 28 Jan, 2010 1 commit
-
-
Tor Didriksen authored
sql/sql_test.cc: Assemble results of all the calls to full_name() first, in order not to garble the tabular output.
-
- 29 Jan, 2010 2 commits
-
-
Ramil Kalimullin authored
-
Georgi Kodinov authored
in multitable delete/subquery SQL_BUFFER_RESULT should not have an effect on non-SELECT statements according to our documentation. Fixed by not passing it through to multi-table DELETE (similarly to how it's done for multi-table UPDATE).
-
- 28 Jan, 2010 3 commits
-
-
Davi Arnaut authored
Rename method as to not hide a base. Reorder attributes initialization. Remove unused variable. Rework code to silence a warning due to assignment used as truth value. sql/item_strfunc.cc: Rename method as to not hide a base. sql/item_strfunc.h: Rename method as to not hide a base. sql/log_event.cc: Reorder attributes initialization. sql/rpl_injector.cc: Rework code to silence a warning due to assignment used as truth value. sql/rpl_record.cc: Remove unused variable. sql/sql_db.cc: Rework code to silence a warning due to assignment used as truth value. sql/sql_parse.cc: Rework code to silence a warning due to assignment used as truth value. sql/sql_table.cc: Rework code to silence a warning due to assignment used as truth value.
-
Andrei Elkin authored
-
Andrei Elkin authored
-
- 27 Jan, 2010 9 commits
-
-
Andrei Elkin authored
merging patches prepared for 5.0 to 5.1-bt. That caused a few changes in the test file
-
Bjorn Munch authored
Define env. vars for both timeout settings Also incorporated 5.0 patch into mtr version 1
-
Staale Smedseng authored
--extended-insert Help message changed to the same as in the 5.1 online documentation.
-
Bjorn Munch authored
Define env. vars for both timeout settings This patch is for 5.0 (mtr v1) and should replaces for 5.1 up
-
Andrei Elkin authored
improving comments
-
Magne Mahre authored
WL#5182 is a follow-up to WL#5154, deprecating a few more options and system variables. client/client_priv.h: The warning message has been changed to not include a specific version number in the text. client/mysql.cc: --no-tee is deprecated client/mysqldump.c: --all is deprecated -a now points to create-options mysql-test/r/mysqlbinlog.result: Warning text changed mysql-test/suite/rpl/r/rpl_row_mysqlbinlog.result: Warning text changed sql/mysql_priv.h: The warning message has been changed to not include a specific version number in the text. sql/mysqld.cc: --use-symbolic-links is deprecated -s now points to --symbolic-links --warnings is deprecated -W now points to --log-warnings myisam_max_extra_sort_file_size is deprecated record_buffer is deprecated --log-update is deprecated --sql-bin-update-same is deprecated --skip-locking is deprecated --skip-symlink is deprecated --enable-locking is deprecated --delay-key-write-for-all-tables is deprecated
-
Staale Smedseng authored
-
Staale Smedseng authored
printstack() being present When Bug#47391 was fixed, no assumption was made that support for Solaris 8 was needed. Solaris 8 lacks printstack(), and the build breaks because of this. This patch adds a test for the presence of printstack() to configure.in for 5.0, and uses HAVE_PRINTSTACK to make decisions rather than the __sun define.
-
unknown authored
The 'rpl_get_master_version_and_clock' test verifies if the slave I/O thread tries to reconnect to master when it tries to get the values of the UNIX_TIMESTAMP, SERVER_ID from master under network disconnection. So the master server is restarted for making the transient network disconnection, during the period the COM_REGISTER_SLAVE failures are produced in server log file when the slave I/O thread tries to register on master. To fix the problem, suppress COM_REGISTER_SLAVE failures in server log file by mtr suppression, because they are expected. mysql-test/suite/rpl/r/rpl_get_master_version_and_clock.result: Removed mtr.add_suppression("Get master clock failed with error: ") and mtr.add_suppression("Get master SERVER_ID failed with error: "). Because they are suppressed globally.
-
- 26 Jan, 2010 3 commits
-
-
Davi Arnaut authored
MySQL's hash functions MD5 and SHA relied on the somewhat slow sprintf function to convert the digests to hex representations. This patch replaces the sprintf with a specific and inline hex conversion function. Patch contributed by Jan Steemann. sql/item_strfunc.cc: Add a hex conversion function.
-
Luis Soares authored
NOTE: added TODO to the comments requested by reviewer during this merge.
-
Georgi Kodinov authored
should be exited before destroying the thread local storage.
-
- 25 Jan, 2010 2 commits
-
-
Andrei Elkin authored
When replicating from 4.1 master to 5.0 slave START SLAVE UNTIL can stop too late. The necessary in calculating of the beginning of an event the event's length did not correspond to the master's genuine information at the event's execution time. That piece of info was changed at the event's relay-logging due to binlog_version<4 event conversion by IO thread. Fixed with storing the master genuine Query_log_event size into a new status variable at relay-logging of the event. The stored info is extacted at the event execution and participate further to caclulate the correct start position of the event in the until-pos stopping routine. The new status variable's algorithm will be only active when the event comes from the master of version < 5.0 (binlog_version < 4). mysql-test/r/rpl_until.result: results changed. mysql-test/std_data/bug47142_master-bin.000001: a binlog from 4.1 master to replace one of the running 5.x master is added as part of Bug #47142 regression test. mysql-test/t/rpl_until.test: Regression test for Bug #47142 is added. sql/log_event.cc: Storing and extracting the master's genuine size of the event from the status var of the event packet header. The binlog_version<4 query-log-event is a. converted into the modern binlog_version==4 to store the original size of the event into a new status var; the converted representation goes into the relay log. b. the converted event is read out and the stored size is engaged in the start pos calculation. The new status is active only for events that IO thread instantiates for the sake of the conversion. sql/log_event.h: Incrementing the max szie of MAX_SIZE_LOG_EVENT_STATUS because of the new status var; Defining the new status variable to hold the master's genuine event size; Augmenting the Query_log_event with a new member to hold a value to store/extact from the status var of the event packet header.
-
unknown authored
sql_udf.cc
-
- 24 Jan, 2010 1 commit
-
-
He Zhenxing authored
-
- 22 Jan, 2010 8 commits
-
-
Sergey Vojtovich authored
-
Sergey Vojtovich authored
Detailed revision comments: r6471 | calvin | 2010-01-16 01:43:27 +0200 (Sat, 16 Jan 2010) | 4 lines branches/5.1: fix bug#49396: main.innodb test fails in embedded mode Change replace_result by using $MYSQLD_DATADIR. Tested in both embedded mode and normal server mode.
-
Sergey Glukhov authored
removed wrongly introduced strlen calls sql/events.cc: removed wrongly introduced strlen calls sql/mysql_priv.h: removed wrongly introduced strlen calls sql/repl_failsafe.cc: removed wrongly introduced strlen calls sql/sql_db.cc: removed wrongly introduced strlen calls sql/sql_parse.cc: removed wrongly introduced strlen calls sql/sql_show.cc: removed wrongly introduced strlen calls
-
Sergey Vojtovich authored
-
Sergey Vojtovich authored
Detailed revision comments: r6492 | sunny | 2010-01-21 09:38:35 +0200 (Thu, 21 Jan 2010) | 1 line branches/5.1: Add reference to bug#47621 in the comment.
-
Sergey Vojtovich authored
Detailed revision comments: r6489 | sunny | 2010-01-21 02:57:50 +0200 (Thu, 21 Jan 2010) | 2 lines branches/5.1: Factor out test for bug#44030 from innodb-autoinc.test into a separate test/result files.
-
Sergey Vojtovich authored
Detailed revision comments: r6488 | sunny | 2010-01-21 02:55:08 +0200 (Thu, 21 Jan 2010) | 2 lines branches/5.1: Factor out test for bug#44030 from innodb-autoinc.test into a separate test/result files.
-
Sergey Vojtovich authored
Detailed revision comments: r6424 | marko | 2010-01-12 12:22:19 +0200 (Tue, 12 Jan 2010) | 16 lines branches/5.1: In innobase_initialize_autoinc(), do not attempt to read the maximum auto-increment value from the table if innodb_force_recovery is set to at least 4, so that writes are disabled. (Bug #46193) innobase_get_int_col_max_value(): Move the function definition before ha_innobase::innobase_initialize_autoinc(), because that function now calls this function. ha_innobase::innobase_initialize_autoinc(): Change the return type to void. Do not attempt to read the maximum auto-increment value from the table if innodb_force_recovery is set to at least 4. Issue ER_AUTOINC_READ_FAILED to the client when the auto-increment value cannot be read. rb://144 by Sunny, revised by Marko
-