Iskren Chernev authored
The Maxim ModelGauge family supports fine-tuning by setting a compensation value (named rcomp in the docs). The value is affected by battery chemistry and ambient temperature. Add support for reading maxim,rcomp from DT and configuring the device with the supplied value. Temperature adjustment is not implemented at the moment, because there is no provision for receiving the ambient temperature at the moment. Signed-off-by: Iskren Chernev <iskren.chernev@gmail.com> Tested-by: Jonathan Bakker <xc-racer2@live.ca> Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
1779c6e3