Jack Morgenstein authored
In procedure mlx4_init_mr_table(), slaves should do no processing, but should return success. This initialization is hypervisor-only. However, the check for num_mpts being a power-of-2 was performed before the check to return immediately if the driver is for a slave. This resulted in spurious failures. The order of performing the checks is reversed, so that if the driver is for a slave, no processing is done and success is returned. Signed-off-by: Jack Morgenstein <jackm@dev.mellanox.co.il> Signed-off-by: Or Gerlitz <ogerlitz@mellanox.com> Signed-off-by: David S. Miller <davem@davemloft.net>
a30f1bc5