• Oskar Schirmer's avatar
    ASoC: fsl: imx-pcm-fiq: remove bogus period delta calculation · 68f9672b
    Oskar Schirmer authored
    Originally snd_hrtimer_callback() used iprtd->period_time for
    some jiffies based estimation to determine the right moment
    to call snd_pcm_period_elapsed(). As timer drifts may well be a
    problem, this was changed in commit b4e82b5b to be based
    on buffer transmission progress, using iprtd->offset and
    runtime->buffer_size to calculate the amount of data since last
    period had elapsed.
    
    Unfortunately, iprtd->offset counts in bytes, while
    runtime->buffer_size counts frames, so adding these to find some
    delta is like comparing apples and oranges, and eventually results
    in negative delta values every now and then. This is no big harm,
    because it simply causes snd_pcm_period_elapsed() being called
    more often than necessary, as negative delta is taken for a
    large unsigned value by implicit conversion rule.
    Nonetheless, the calculation is broken, so one would replace
    the runtime->buffer_size by its equivalent in bytes.
    
    But then, there are chances snd_pcm_period_elapsed() is called
    late, because calculating the moment for the elapsed period
    into delta is based against the iprtd->last_offset, which is not
    necessarily the first byte of the period in question, but some
    random byte which the FIQ handler left us with in r8/r9 by
    accident. Again, negative impact is low, as there are plenty of
    periods already prefilled with data, and snd_pcm_period_elapsed()
    will probably be called latest when the following period is
    reached. However, the calculation is conceptually broken, and we
    are best off removing the clever stuff altogether.
    
    snd_pcm_period_elapsed() is now simply called once everytime
    snd_hrtimer_callback() is run, which may not be most accurate,
    but at least this way we are quite sure we dont miss an end of
    period. There is not much extra effort wasted by superfluous
    calls to snd_pcm_period_elapsed(), as the timer frequency
    closely matches the period size anyway.
    Signed-off-by: default avatarOskar Schirmer <oskar@scara.com>
    Signed-off-by: default avatarMark Brown <broonie@linaro.org>
    68f9672b