Abhilash Kesavan authored
Add registers, bit fields and compatible strings for Exynos7 TMU (Thermal Management Unit). Following are a few of the differences in the Exynos7 TMU from earlier SoCs: - 8 trigger levels - Different bit offsets and more registers for the rising and falling thresholds. - New power down detection bit in the TMU_CONTROL register which does not update the CURRENT_TEMP0 when tmu power down is detected. - Change in bit offset for the NEXT_DATA field of EMUL_CON register. EMUL_CON register address has also changed. - INTSTAT and INTCLEAR registers present in earlier SoCs have been combined into one INTPEND register. The register address for INTCLEAR and INTPEND is also different. - Since there are 8 rising/falling interrupts as against at most 4 in earlier SoCs the INTEN bit offsets are different. - Multiple probe support which is handled by a TMU_CONTROL1 register (No support for this in the current patch). This patch adds special clock support required only for Exynos7. It also updates the "code_to_temp" prototype as Exynos7 has 9 bit code-temp mapping. Acked-by: Lukasz Majewski <l.majewski@samsung.com> Tested-by: Lukasz Majewski <l.majewski@samsung.com> Signed-off-by: Abhilash Kesavan <a.kesavan@samsung.com> Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
6c247393