Imre Deak authored
The PPS registers are backed by power well #0 and as such may be reset after system or runtime suspend (both implying a possible DC9 transition). Fix this by reusing the VLV/CHV PPS pipe-reassignment logic. The difference on BXT is that the PPS instances are not pipe but port (or more accurately pin) specific, so we only need to care about the lost HW state. As opposed to VLV/CHV the SW state is fixed and initialized during connector init. This also paves the way towards using the actual port->PPS instance mapping based on VBT. This fixes eDP link training errors on BXT after suspend, where we started the link training too early due to an incorrect T3 (panel power on) register value. Bugzilla: https://bugs.freedesktop.org/show_bug.cgi?id=96436Signed-off-by: Imre Deak <imre.deak@intel.com> Reviewed-by: Ville Syrjälä <ville.syrjala@linux.intel.com> Link: http://patchwork.freedesktop.org/patch/msgid/1466084243-5388-2-git-send-email-imre.deak@intel.com
78597996