Christophe JAILLET authored
If an error occurs when we enable the backup battery charging, we should go through the error handling path directly. Before commit db43e6c4 ("ab8500-bm: Add usb power path support") this was the case, but this commit has added some code between the last test and the 'out' label. So, in case of error, this added code is executed and the error may be silently ignored. Fix it by adding the missing 'goto out', as done in all other error handling paths. Fixes: db43e6c4 ("ab8500-bm: Add usb power path support") Signed-off-by: Christophe JAILLET <christophe.jaillet@wanadoo.fr> Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.co.uk>
09edcb64