Peter Ujfalusi authored
Let the codec to hit OFF instead of STANDBY, when there is no activity. When the codec is off, than the associated regulator can be also turned off (if the number of users on the regulator is 0). After initialization, the codec remains in power off, it is only turned on for reading the ID registers (also testing the regulators). The codec power is enabled, when the codec is moving from BIAS_OFF to BIAS_STANDBY. The codec is turned off, when it hits BIAS_OFF. There are few scenarios, which has to be taken care:: 1. Analog bypass caused BIAS_OFF -> BIAS_ON We need to power on the codec, and do the chip init, but we does not need to execute the playback related configuration 2. Playback caused BIAS_OFF -> BIAS_ON We need to power on the codec, and do the chip init, and also we need to execute the playback related configuration. 3. Playback start, while Analog bypass is on (BIAS_ON -> BIAS_ON) We need to execute the playback related configuration. The codec is already on. 4. Analog bypass enable, while playback (BIAS_ON -> BIAS_ON) Nothing need to be done. 5. Playback start withing soc power down timeout (BIAS_ON -> BIAS_ON) We need to execute the playback related configuration. The codec is still on. Since the power up, and the codec init is optimized, the added overhead in stream start is minimal. Withing this patch, the hard_power function is now only doing what it supposed to: only handle the powers, and GPIO reset line. The codec initialization and state restore has been moved out. Signed-off-by: Peter Ujfalusi <peter.ujfalusi@nokia.com> Acked-by: Mark Brown <broonie@opensource.wolfsonmicro.com> Signed-off-by: Liam Girdwood <lrg@slimlogic.co.uk>
ad05c03b