Claudiu Beznea authored
For HLCDC timing engine configurations bit ATMEL_HLCDC_SIP of ATMEL_HLCDC_SR needs to be polled before applying new config. In case of timeout there is no indicator about this, so, return in case of timeout and also print a message about this. Signed-off-by: Claudiu Beznea <claudiu.beznea@microchip.com> Signed-off-by: Lee Jones <lee.jones@linaro.org>