Vladislav Bolkhovitin authored
Currently it is impossible to reset provided by Qlogic QLA2xxx driver SCSI devices externally using corresponding sg devices, particularly via sg_reset utility, because qla2xxx driver in qla2xxx_eh_device_reset() function checks if the input scsi_cmnd has its private data (CMD_SP()) attached. Then the found pointer isn't used anywhere inside of qla2xxx_eh_device_reset(). If the RESET request comes from sg device, it doesn't have such private data. The attached patch removes check for non-NULL CMD_SP() from qla2xxx_eh_device_reset(), hence allows to reset QLA2xxx's devices using corresponding sg devices. AV: change applies to bus/host reset handlers as well. Signed-off-by: Vladislav Bolkhovitin <vst@vlnb.net> Signed-off-by: Andrew Vasquez <andrew.vasquez@qlogic.com> Signed-off-by: James Bottomley <James.Bottomley@SteelEye.com>
b0328bee