-
Peter Hung authored
Fix RS232/485 mode incorrect setting after S3/S4 resume for F81504/508/512 We had add RS232/485 RTS control with fecf27a3. But when it resume from S3/S4, the mode register 0x40 + 0x08 * idx + 7 will rewrite to 0x01 (RS232 mode). This patch will modify 2 sections. One is pci_fintek_init(), if it called when first init, it will write mode register with 0x01. If it called from S3/S4 resume, it's will get the relative port data and pass it to pci_fintek_rs485_config() with NULL rs485 parameter. The another modification is in pci_fintek_rs485_config(). It'll re-apply old configuration when the parameter rs485 is NULL. Signed-off-by: Peter Hung <hpeter+linux_kernel@gmail.com> Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
d3159455