Laxman Dewangan authored
As per datasheet, voltage range for LDOs are as follows: 0000 = 0.9V ...(50mV steps) 01111 = 1.65V 10000 = 1.8V ... (100mV stepns) 11111 = 3.3V So, there is no selector for 1.65V to 1.8V. Correcting the range for max_uV for selector between 0 to 15. Signed-off-by: Laxman Dewangan <ldewangan@nvidia.com> Signed-off-by: Mark Brown <broonie@linaro.org>