Akira Shimahara authored
Adding device alarms settings by a dedicated sysfs entry alarms (RW): read or write TH and TL in the device RAM. Checking devices in alarm state could be performed using the master search command. As alarms temperature level are store in a 8 bit register on the device and are signed values, a safe cast shall be performed using the min and max temperature that device are able to measure. This is done by int_to_short inline function. A 'write_data' field is added in the device structure, to bind the correct writing function, as some devices may have 2 or 3 bytes RAM. Updating Documentation/ABI/testing/sysfs-driver-w1_therm accordingly. Signed-off-by: Akira Shimahara <akira215corp@gmail.com> Link: https://lore.kernel.org/r/20200511203801.411253-1-akira215corp@gmail.comSigned-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>