hwmon: (f75375s) Fix automatic pwm mode setting for F75373 & F75375

In order to enable temperature mode aka automatic mode for the F75373 and
F75375 chips, the two FANx_MODE bits in the fan configuration register
need be set to 01, not 10.
Signed-off-by: default avatarNikolaus Schulz <mail@microschulz.de>
Cc: stable@kernel.org # 2.6.32+
Signed-off-by: default avatarGuenter Roeck <guenter.roeck@ericsson.com>
parent eb564e1d
...@@ -369,7 +369,7 @@ static int set_pwm_enable_direct(struct i2c_client *client, int nr, int val) ...@@ -369,7 +369,7 @@ static int set_pwm_enable_direct(struct i2c_client *client, int nr, int val)
fanmode |= (3 << FAN_CTRL_MODE(nr)); fanmode |= (3 << FAN_CTRL_MODE(nr));
break; break;
case 2: /* AUTOMATIC*/ case 2: /* AUTOMATIC*/
fanmode |= (2 << FAN_CTRL_MODE(nr)); fanmode |= (1 << FAN_CTRL_MODE(nr));
break; break;
case 3: /* fan speed */ case 3: /* fan speed */
break; break;
......