net: phy: smsc: Fix disabling energy detect mode
When the lan87xx_read_status function is getting called the energy detect mode is enabled again even if it has been disabled by device tree. Added private struct to check the energy detect status. Signed-off-by: Teresa Remmet <t.remmet@phytec.de> Signed-off-by: David S. Miller <davem@davemloft.net>