[SCSI] mpt2sas: Infinite loop can occur if MPI2_IOCSTATUS_CONFIG_INVALID_PAGE is not returned
Infinite loop can occur if IOCStatus is not equal to MPI2_IOCSTATUS_CONFIG_INVALID_PAGE value in the while loops in functions _scsih_search_responding_sas_devices, _scsih_search_responding_raid_devices and _scsih_search_responding_expanders So, Instead of checking for MPI2_IOCSTATUS_CONFIG_INVALID_PAGE value, in this patch code is modified to check for IOCStatus not equals to MPI2_IOCSTATUS_SUCCESS to break the while loop. Signed-off-by: Sreekanth Reddy <Sreekanth.Reddy@lsi.com> Signed-off-by: James Bottomley <JBottomley@Parallels.com>