power: bq25890: fix ADC mode configuration

Datasheet describes two modes for reading ADC measurements:
1. continuous, 1 Hz - enabled and started by CONV_RATE bit
2. one-shot - triggered by CONV_START bit

In continuous mode, CONV_START is read-only and signifies an ongoing
conversion.

Change the code to follow the datasheet and really disable continuous
mode for power saving.
Signed-off-by: default avatarMichał Mirosław <mirq-linux@rere.qmqm.pl>
Signed-off-by: default avatarSebastian Reichel <sebastian.reichel@collabora.com>
parent 1e4724d0
......@@ -126,6 +126,7 @@ static const struct regmap_access_table bq25890_writeable_regs = {
static const struct regmap_range bq25890_volatile_reg_ranges[] = {
regmap_reg_range(0x00, 0x00),
regmap_reg_range(0x02, 0x02),
regmap_reg_range(0x09, 0x09),
regmap_reg_range(0x0b, 0x14),
};
......@@ -374,18 +375,38 @@ enum bq25890_chrg_fault {
CHRG_FAULT_TIMER_EXPIRED,
};
static bool bq25890_is_adc_property(enum power_supply_property psp)
{
switch (psp) {
case POWER_SUPPLY_PROP_VOLTAGE_NOW:
case POWER_SUPPLY_PROP_CURRENT_NOW:
return true;
default:
return false;
}
}
static int bq25890_power_supply_get_property(struct power_supply *psy,
enum power_supply_property psp,
union power_supply_propval *val)
{
int ret;
struct bq25890_device *bq = power_supply_get_drvdata(psy);
struct bq25890_state state;
bool do_adc_conv;
int ret;
mutex_lock(&bq->lock);
state = bq->state;
do_adc_conv = !state.online && bq25890_is_adc_property(psp);
if (do_adc_conv)
bq25890_field_write(bq, F_CONV_START, 1);
mutex_unlock(&bq->lock);
if (do_adc_conv)
regmap_field_read_poll_timeout(bq->rmap_fields[F_CONV_START],
ret, !ret, 25000, 1000000);
switch (psp) {
case POWER_SUPPLY_PROP_STATUS:
if (!state.online)
......@@ -623,8 +644,8 @@ static int bq25890_hw_init(struct bq25890_device *bq)
}
}
/* Configure ADC for continuous conversions. This does not enable it. */
ret = bq25890_field_write(bq, F_CONV_RATE, 1);
/* Configure ADC for continuous conversions when charging */
ret = bq25890_field_write(bq, F_CONV_RATE, !!bq->state.online);
if (ret < 0) {
dev_dbg(bq->dev, "Config ADC failed %d\n", ret);
return ret;
......@@ -966,7 +987,7 @@ static int bq25890_suspend(struct device *dev)
* If charger is removed, while in suspend, make sure ADC is diabled
* since it consumes slightly more power.
*/
return bq25890_field_write(bq, F_CONV_START, 0);
return bq25890_field_write(bq, F_CONV_RATE, 0);
}
static int bq25890_resume(struct device *dev)
......@@ -982,7 +1003,7 @@ static int bq25890_resume(struct device *dev)
/* Re-enable ADC only if charger is plugged in. */
if (bq->state.online) {
ret = bq25890_field_write(bq, F_CONV_START, 1);
ret = bq25890_field_write(bq, F_CONV_RATE, 1);
if (ret < 0)
goto unlock;
}
......