ath9k: interleaved NF calibration on AR9002
NF calibration and other elements of long calibration are usually faster than ADCs & I/Q calibrations due to independence of receiption of the OFDM signal. Moreover sometime I/Q calibration can not be completed at all without preceding NF calibration. This is due to AGC, which has a habit to block a weak signal without regular NF calibration. Thus, we do not need to deferr the long calibration forever. So, if the long calibration is requested, then deferr the ADCs & I/Q calibration(s) and run the longcal (the NF calibration in particular) to obtain fresh noise data. Run tested with AR9220. Signed-off-by: Sergey Ryazanov <ryazanov.s.a@gmail.com> Signed-off-by: Kalle Valo <kvalo@codeaurora.org> Link: https://lore.kernel.org/r/20200424004923.17129-5-ryazanov.s.a@gmail.com