Commit 4359db1e authored by Eugenia Emantayev's avatar Eugenia Emantayev Committed by David S. Miller

net/mlx4_en: Run loopback test only when port is up

Loopback can't work when port is down.
Signed-off-by: default avatarEugenia Emantayev <eugenia@mellanox.com>
Signed-off-by: default avatarAmir Vadai <amirv@mellanox.com>
Signed-off-by: default avatarDavid S. Miller <davem@davemloft.net>
parent 523ece88
......@@ -159,7 +159,8 @@ void mlx4_en_ex_selftest(struct net_device *dev, u32 *flags, u64 *buf)
if (priv->mdev->dev->caps.flags &
MLX4_DEV_CAP_FLAG_UC_LOOPBACK) {
buf[3] = mlx4_en_test_registers(priv);
buf[4] = mlx4_en_test_loopback(priv);
if (priv->port_up)
buf[4] = mlx4_en_test_loopback(priv);
}
if (carrier_ok)
......
Markdown is supported