staging: comedi: ni_mio_common: use insn->n in ni_m_series_eeprom_insn_read()
The `insn_read` handler for the EEPROM subdevice on M-series boards (`ni_m_series_eeprom_insn_read()`) currently ignores `insn->n` (the number of samples to read) and assumes a single sample is to be read into `data[0]`. Fortunately, the Comedi core ensures that `data[]` has a length of at least 16 so there is no problem with array bounds. The usual Comedi convention for `insn_read` handlers is to read the same channel `insn->n` times into successive elements of `data[]` so let's do that. (Each channel corresponds to a single EEPROM address.) In this case, the data value comes from a local copy of the EEPROM contents. Also, follow the usual Comedi convention and return `insn->n` from the handler to indicate success (although any non-negative value will do). Signed-off-by: Ian Abbott <abbotti@mev.co.uk> Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>