clockevents/drivers/atlas7: Set ->min_delta_ticks and ->max_delta_ticks
In preparation for making the clockevents core NTP correction aware, all clockevent device drivers must set ->min_delta_ticks and ->max_delta_ticks rather than ->min_delta_ns and ->max_delta_ns: a clockevent device's rate is going to change dynamically and thus, the ratio of ns to ticks ceases to stay invariant. Make the timer-atlas7 clockevent driver initialize these fields properly. This patch alone doesn't introduce any change in functionality as the clockevents core still looks exclusively at the (untouched) ->min_delta_ns and ->max_delta_ns. As soon as this has changed, a followup patch will purge the initialization of ->min_delta_ns and ->max_delta_ns from this driver. Cc: Ingo Molnar <mingo@redhat.com> Cc: Thomas Gleixner <tglx@linutronix.de> Cc: Daniel Lezcano <daniel.lezcano@linaro.org> Cc: Richard Cochran <richardcochran@gmail.com> Cc: Prarit Bhargava <prarit@redhat.com> Cc: Stephen Boyd <sboyd@codeaurora.org> Cc: Barry Song <baohua@kernel.org> Cc: linux-arm-kernel@lists.infradead.org Acked-by: Daniel Lezcano <daniel.lezcano@linaro.org> Signed-off-by: Nicolai Stange <nicstange@gmail.com> Signed-off-by: John Stultz <john.stultz@linaro.org>