Commit 6cb0ac0f authored by Adam Ford's avatar Adam Ford Committed by Tony Lindgren

ARM: dts: ARM: dts: Configure interconnect target module for am3517sgx

Based on Tony Lindgren's work for omap34xx, this patch applies the same
functionality to the AM3517.

The following can be tested via sysfs with the following to ensure the SGX
module gets enabled and disabled properly:

0x00010201

Bus error

Cc: Filip Matijević <filip.matijevic.pz@gmail.com>
Cc: "H. Nikolaus Schaller" <hns@goldelico.com>
Cc: Ivaylo Dimitrov <ivo.g.dimitrov.75@gmail.com>
Cc: moaz korena <moaz@korena.xyz>
Cc: Merlijn Wajer <merlijn@wizzup.org>
Cc: Paweł Chmiel <pawel.mikolaj.chmiel@gmail.com>
Cc: Philipp Rossak <embed3d@gmail.com>
Cc: Tomi Valkeinen <tomi.valkeinen@ti.com>
Signed-off-by: default avatarAdam Ford <aford173@gmail.com>
[tony@atomide.com: updated subject, dropped rstctrl info]
Signed-off-by: default avatarTony Lindgren <tony@atomide.com>
parent 3b72fc89
......@@ -88,6 +88,30 @@ hecc: can@5c050000 {
interrupts = <24>;
clocks = <&hecc_ck>;
};
/*
* On am3517 the OCP registers do not seem to be accessible
* similar to the omap34xx. Maybe SGX is permanently set to
* "OCP bypass mode", or maybe there is OCP_SYSCONFIG that is
* write-only at 0x50000e10. We detect SGX based on the SGX
* revision register instead of the unreadable OCP revision
* register.
*/
sgx_module: target-module@50000000 {
compatible = "ti,sysc-omap2", "ti,sysc";
reg = <0x50000014 0x4>;
reg-names = "rev";
clocks = <&sgx_fck>, <&sgx_ick>;
clock-names = "fck", "ick";
#address-cells = <1>;
#size-cells = <1>;
ranges = <0 0x50000000 0x4000>;
/*
* Closed source PowerVR driver, no child device
* binding or driver in mainline
*/
};
};
};
......
Markdown is supported
0%
or
You are about to add 0 people to the discussion. Proceed with caution.
Finish editing this message first!