clk: samsung: exynos7: Fix PLL rates
Rates declared in PLL rate tables should match exactly rates calculated from the PLL coefficients. If that is not the case, rate of the PLL's child clock might be set not as expected. For instance, if in the PLL rates table we have a 393216000 Hz entry and the real value as returned by the PLL's recalc_rate callback is 393216003, after setting PLL's clk rate to 393216000 clk_get_rate will return 393216003. If we now attempt to set rate of a PLL's child divider clock to 393216000/2 its rate will be 131072001, rather than 196608000. That is, the divider will be set to 3 instead of 2, because 393216003/2 is greater than 196608000. To fix this issue declared rates are changed to exactly match rates generated by the PLL, as calculated from the P, M, S, K coefficients. Signed-off-by: Andrzej Hajda <a.hajda@samsung.com> Acked-by: Tomasz Figa <tomasz.figa@gmail.com> Acked-by: Chanwoo Choi <cw00.choi@samsung.com> Signed-off-by: Sylwester Nawrocki <s.nawrocki@samsung.com>
Showing
Please register or sign in to comment