MIPS: Use unsigned int when reading CP0 registers
Update __read_32bit_c0_register() and __read_32bit_c0_ctrl_register() to use "unsigned int res;" instead of "int res;". There is little reason to treat these register values as signed. They are either counters (which by definition are unsigned) or are made up of various bit fields to be interpreted as per the CPU datasheet. This has come up via u-boot[1] which sync's asm/mipsregs.h with the kernel. In u-boots case the value read from read_c0_count() is assigned to an unsigned long [2] which triggers a sign extension and causes a bug. U-boot should probably be more explicit about the types used for the timer_read_counter() API but that aside is there any reason to treat these values as signed integers? A quick grep around the arch/mips makes me thing that there may be some bugs lurking when read_c0_count() starts to yield a negative value but I haven't really explored any of them. [1] - http://lists.denx.de/pipermail/u-boot/2015-July/219086.html [2] - http://git.denx.de/?p=u-boot.git;a=blob;f=arch/mips/cpu/time.c#l11Signed-off-by: Chris Packham <judge.packham@gmail.com> Cc: linux-mips@linux-mips.org Cc: Daniel Schwierzeck <daniel.schwierzeck@gmail.com> Cc: Chris Packham <judge.packham@gmail.com> Cc: Steven J. Hill <Steven.Hill@imgtec.com> Cc: Maciej W. Rozycki <macro@linux-mips.org> Cc: linux-kernel@vger.kernel.org Cc: James Hogan <james.hogan@imgtec.com> Cc: Markos Chandras <markos.chandras@imgtec.com> Cc: Paul Burton <paul.burton@imgtec.com> Patchwork: https://patchwork.linux-mips.org/patch/10718/Signed-off-by: Ralf Baechle <ralf@linux-mips.org>