Commit 879d7362 authored by Miquel Raynal's avatar Miquel Raynal Committed by Eduardo Valentin

thermal: armada: add overheat interrupt support

The IP can manage to trigger interrupts on overheat situation from all
the sensors.

However, the interrupt source changes along with the last selected
source (ie. the last read sensor), which is an inconsistent behavior.
Avoid possible glitches by always selecting back only one channel which
will then be referenced as the "overheat_sensor" (arbitrarily: the first
in the DT which has a critical trip point filled in).

It is possible that the scan of all thermal zone nodes did not bring a
critical trip point from which the overheat interrupt could be
configured. In this case just complain but do not fail the probe.

Also disable sensor switch during overheat situations because changing
the channel while the system is too hot could clear the overheat state
by changing the source while the temperature is still very high.

Even if the overheat state is not declared, overheat interrupt must be
cleared by reading the DFX interrupt cause _after_ the temperature has
fallen down to the low threshold, otherwise future possible interrupts
would not be served. A work polls the corresponding register until the
overheat flag gets cleared in this case.
Suggested-by: default avatarDavid Sniatkiwicz <davidsn@marvell.com>
Signed-off-by: default avatarMiquel Raynal <miquel.raynal@bootlin.com>
Signed-off-by: default avatarEduardo Valentin <edubezval@gmail.com>