Commit 9dbf8ccd authored by Lars-Peter Clausen's avatar Lars-Peter Clausen Committed by Jonathan Cameron

iio: Add some helper macros for unit conversion

Some datasheets use a different unit to specify the channel scale than what IIO
expects it to be. This patch adds two helper macros which allow to convert units
commonly used in datasheets to IIO units:

 * acceleration: g -> meter / second**2
 * angular velocity: degree (/ second) -> rad (/ second)

This makes it much more convenient to specify and also easier to verify a
channel's scale attribute.
Signed-off-by: default avatarLars-Peter Clausen <lars@metafoo.de>
Signed-off-by: default avatarJonathan Cameron <jic23@kernel.org>
parent ddffeb8c
...@@ -618,4 +618,20 @@ static inline struct dentry *iio_get_debugfs_dentry(struct iio_dev *indio_dev) ...@@ -618,4 +618,20 @@ static inline struct dentry *iio_get_debugfs_dentry(struct iio_dev *indio_dev)
}; };
#endif #endif
/**
* IIO_DEGREE_TO_RAD() - Convert degree to rad
* @deg: A value in degree
*
* Returns the given value converted from degree to rad
*/
#define IIO_DEGREE_TO_RAD(deg) (((deg) * 314159ULL + 9000000ULL) / 18000000ULL)
/**
* IIO_G_TO_M_S_2() - Convert g to meter / second**2
* @g: A value in g
*
* Returns the given value converted from g to meter / second**2
*/
#define IIO_G_TO_M_S_2(g) ((g) * 980665ULL / 100000ULL)
#endif /* _INDUSTRIAL_IO_H_ */ #endif /* _INDUSTRIAL_IO_H_ */