Commit a7c44d4a authored by Christoph Hellwig's avatar Christoph Hellwig Committed by James Bottomley

[SCSI] mpt2sas: do not check serial_number in the abort handler

The SCSI midlayer stops all command processing when in error handling, which
means there is no chance for command reuse when the abort handler is called.
Signed-off-by: default avatarChristoph Hellwig <hch@lst.de>
Acked-by: default avatar"Moore, Eric" <Eric.Moore@lsi.com>
Signed-off-by: default avatarJames Bottomley <James.Bottomley@suse.de>
parent 05d1091f
......@@ -2133,8 +2133,7 @@ mpt2sas_scsih_issue_tm(struct MPT2SAS_ADAPTER *ioc, u16 handle, uint channel,
switch (type) {
case MPI2_SCSITASKMGMT_TASKTYPE_ABORT_TASK:
scmd_lookup = _scsih_scsi_lookup_get(ioc, smid_task);
if (scmd_lookup && (scmd_lookup->serial_number ==
scmd->serial_number))
if (scmd_lookup)
rc = FAILED;
else
rc = SUCCESS;
......