net: phy: at803x: fix clock sink configuration on ATH8030 and ATH8035
The masks in priv->clk_25m_reg and priv->clk_25m_mask are one-bits-set for the values that comprise the fields, not zero-bits-set. This patch fixes the clock frequency configuration for ATH8030 and ATH8035 Atheros PHYs by removing the erroneous "~". To reproduce this bug, configure the PHY with the device tree binding "qca,clk-out-frequency" and remove the machine specific PHY fixups. Fixes: 2f664823 ("net: phy: at803x: add device tree binding") Signed-off-by: Oleksij Rempel <o.rempel@pengutronix.de> Reported-by: Russell King <rmk+kernel@armlinux.org.uk> Reviewed-by: Russell King <rmk+kernel@armlinux.org.uk> Tested-by: Russell King <rmk+kernel@armlinux.org.uk> Signed-off-by: David S. Miller <davem@davemloft.net>