Commit c23e253e authored by Andreas Herrmann's avatar Andreas Herrmann Committed by Ingo Molnar

x86: hpet: stop HPET_COUNTER when programming periodic mode

Impact: fix system hang on some systems operating with HZ_1000

On a system that stalled with HZ_1000, the first value written to
T0_CMP (when the main counter was not stopped) did not trigger an
interrupt. Instead after the main counter wrapped around (after
several minutes) an interrupt was triggered and afterwards the
periodic interrupt took effect.

This can be fixed by implementing HPET spec recommendation for
programming the periodic mode (i.e. stopping the main counter).
Signed-off-by: default avatarAndreas Herrmann <andreas.herrmann3@amd.com>
Cc: Mark Hounschell <markh@compro.net>
Cc: Borislav Petkov <borislav.petkov@amd.com>
Signed-off-by: default avatarIngo Molnar <mingo@elte.hu>
parent 8d6f0c82
......@@ -309,29 +309,22 @@ static int hpet_setup_msi_irq(unsigned int irq);
static void hpet_set_mode(enum clock_event_mode mode,
struct clock_event_device *evt, int timer)
{
unsigned long cfg, cmp, now;
unsigned long cfg;
uint64_t delta;
switch (mode) {
case CLOCK_EVT_MODE_PERIODIC:
hpet_stop_counter();
delta = ((uint64_t)(NSEC_PER_SEC/HZ)) * evt->mult;
delta >>= evt->shift;
now = hpet_readl(HPET_COUNTER);
cmp = now + (unsigned long) delta;
cfg = hpet_readl(HPET_Tn_CFG(timer));
/* Make sure we use edge triggered interrupts */
cfg &= ~HPET_TN_LEVEL;
cfg |= HPET_TN_ENABLE | HPET_TN_PERIODIC |
HPET_TN_SETVAL | HPET_TN_32BIT;
hpet_writel(cfg, HPET_Tn_CFG(timer));
/*
* The first write after writing TN_SETVAL to the
* config register sets the counter value, the second
* write sets the period.
*/
hpet_writel(cmp, HPET_Tn_CMP(timer));
udelay(1);
hpet_writel((unsigned long) delta, HPET_Tn_CMP(timer));
hpet_start_counter();
hpet_print_config();
break;
......