iio: adc: ad7606: Add support for software mode for ad7616
Support for ad7616 running in software was added. In order to activate the software mode, HW_RNGSEL pins must be pulled low. Oversampling and input ranges are now configured in corresponding registers. Ad7616 has multiple scale options when it is configured in software mode. Also, in order to support multiple devices in software mode, the spi calculation of registers address must be generic. Because the length of address and bit which specifies the read/write operation is different for every device, calculation of address was made generic. Signed-off-by: Beniamin Bia <beniamin.bia@analog.com> Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>