- 22 Mar, 2012 40 commits
-
-
Alex Elder authored
A few blocks of code are rearranged a bit here: - In rbd_header_from_disk(): - Don't bother computing snap_count until we're sure the on-disk header starts with a good signature. - Move a few independent lines of code so they are *after* a check for a failed memory allocation. - Get rid of unnecessary local variable "ret". - Make a few other changes in rbd_read_header(), similar to the above--just moving things around a bit while preserving the functionality. - In rbd_rq_fn(), just assign rq in the while loop's controlling expression rather than duplicating it before and at the end of the loop body. This allows the use of "continue" rather than "goto next" in a number of spots. - Rearrange the logic in snap_by_name(). End result is the same. Signed-off-by: Alex Elder <elder@dreamhost.com>
-
Alex Elder authored
Once rbd_bus_type is registered, it allows an "add" operation via the /sys/bus/rbd/add bus attribute, and adding a new rbd device that way establishes a connection between the device and rbd_root_dev. But rbd_root_dev is not registered until after the rbd_bus_type registration is complete. This could (in principle anyway) result in an invalid state. Since rbd_root_dev has no tie to rbd_bus_type we can reorder these two initializations and never be faced with this scenario. In addition, unregister the device in the event the bus registration fails at module init time. Signed-off-by: Alex Elder <elder@dreamhost.com> Signed-off-by: Sage Weil <sage@newdream.net>
-
Alex Elder authored
The mon_addrs buffer in rbd_add is used to hold a copy of the monitor IP addresses supplied via /sys/bus/rbd/add. That is passed to rbd_get_client(), which never modifies it (nor do any of the functions it gets passed to thereafter)--the mon_addr parameter to rbd_get_client() is a pointer to constant data, so it can't be modifed. Furthermore, rbd_get_client() has the length of the mon_addrs buffer and that is used to ensure nothing goes beyond its end. Based on all this, there is no reason that a buffer needs to be used to hold a copy of the mon_addrs provided via /sys/bus/rbd/add. Instead, the location within that passed-in buffer can be provided, along with the length of the "token" therein which represents the monitor IP's. A small change to rbd_add_parse_args() allows the address within the buffer to be passed back, and the length is already returned. This now means that, at least from the perspective of this interface, there is no such thing as a list of monitor addresses that is too long. Signed-off-by: Alex Elder <elder@dreamhost.com>
-
Alex Elder authored
The argument parsing routine already computes the size of the mon_addrs buffer it extracts from the "command." Pass it to the caller so it can use it to provide the length to rbd_get_client(). Signed-off-by: Alex Elder <elder@dreamhost.com>
-
Alex Elder authored
This is a bit gratuitous, but there are a few things that can be verified at build time rather than run time, so do that. Signed-off-by: Alex Elder <elder@dreamhost.com>
-
Alex Elder authored
Make use of a few simple helper routines to parse the arguments rather than sscanf(). This will treat both missing and too-long arguments as invalid input (rather than silently truncating the input in the too-long case). In time this can also be used by rbd_add() to use the passed-in buffer in place, rather than copying its contents into new buffers. It appears to me that the sscanf() previously used would not correctly handle a supplied snapshot--the two final "%s" conversion specifications were not separated by a space, and I'm not sure how sscanf() handles that situation. It may not be well-defined. So that may be a bug this change fixes (but I didn't verify that). The sizes of the mon_addrs and options buffers are now passed to rbd_add_parse_args(), so they can be supplied to copy_token(). Signed-off-by: Alex Elder <elder@dreamhost.com>
-
Alex Elder authored
Move the code that parses the arguments provided to rbd_add() (which are supplied via /sys/bus/rbd/add) into a separate function. Also rename the "mon_dev_name" variable in rbd_add() to be "mon_addrs". The variable represents a list of one or more comma-separated monitor IP addresses, each with an optional port number. I think "mon_addrs" captures that notion a little better. Signed-off-by: Alex Elder <elder@dreamhost.com>
-
Alex Elder authored
If a couple pointers are initialized to NULL then a single "out_nomem" label can be used for all of the memory allocation failure cases in rbd_add(). Also, get rid of the "irc" local variable there. There is no real need for "rc" to be type ssize_t, and it can be used in the spot "irc" was. Signed-off-by: Alex Elder <elder@dreamhost.com> Signed-off-by: Sage Weil <sage@newdream.net>
-
Alex Elder authored
The length of the string containing the monitor address specification(s) will never exceed the length of the string passed in to rbd_add(). The same holds true for the ceph + rbd options string. So reduce the amount of memory allocated for these to that length rather than the maximum (1024 bytes). Signed-off-by: Alex Elder <elder@dreamhost.com> Signed-off-by: Sage Weil <sage@newdream.net>
-
Alex Elder authored
Since rbd_get_client() currently returns an error code. It assigns the rbd_client field of the rbd_device structure it is passed if successful. Instead, have it return the created rbd_client structure and return a pointer-coded error if there is an error. This makes the assignment of the client pointer more obvious at the call site. Signed-off-by: Alex Elder <elder@dreamhost.com> Signed-off-by: Sage Weil <sage@newdream.net>
-
Alex Elder authored
Here are a few very simple cleanups: - Add a "RBD_" prefix to the two driver name string definitions. - Move the definition of struct rbd_request below struct rbd_req_coll to avoid the need for an empty declaration of the latter. - Move and group the definitions of rbd_root_dev_release() and rbd_root_dev, as well as rbd_bus_type and rbd_bus_attrs[], close to the top of the file. Arrange the latter so rbd_bus_type.bus_attrs can be initialized statically. - Get rid of an unnecessary local variable in rbd_open(). - Rework some hokey logic in rbd_bus_add_dev(), so the value of "ret" at the end is either 0 or -ENOENT to avoid the need for the code duplication that was there. - Rename a goto target in rbd_add(). Signed-off-by: Alex Elder <elder@dreamhost.com> Signed-off-by: Sage Weil <sage@newdream.net>
-
Alex Elder authored
The spinlock used to protect rbd_client_list is named "node_lock". Rename it to "rbd_client_list_lock" to make it more obvious what it's for. Signed-off-by: Alex Elder <elder@dreamhost.com> Signed-off-by: Sage Weil <sage@newdream.net>
-
Alex Elder authored
Since rbd_client_create() is only called in one place, move the acquisition of the mutex around that call inside that function. Signed-off-by: Alex Elder <elder@dreamhost.com> Signed-off-by: Sage Weil <sage@newdream.net>
-
Alex Elder authored
Since rbd_get_client() is only called in one place, move the acquisition of the mutex around that call inside that function. Furthermore, within rbd_get_client(), it appears the mutex only needs to be held while calling rbd_client_create(). (Moving the lock inside that function will wait for the next patch.) Signed-off-by: Alex Elder <elder@dreamhost.com> Signed-off-by: Sage Weil <sage@newdream.net>
-
Alex Elder authored
In rbd_get_client(), if a client is reused, a number of things get done while still holding the list lock unnecessarily. This just moves a few things that need no lock protection outside the lock. Signed-off-by: Alex Elder <elder@dreamhost.com> Signed-off-by: Sage Weil <sage@newdream.net>
-
Alex Elder authored
It used to be that selecting a new unique identifier for an added rbd device required searching all existing ones to find the highest id is used. A recent change made that unnecessary, but made it so that id's used were monotonically non-decreasing. It's a bit more pleasant to have smaller rbd id's though, and this change makes ids get allocated as they were before--each new id is one more than the maximum currently in use. Signed-off-by: Alex Elder <elder@dreamhost.com> Signed-off-by: Sage Weil <sage@newdream.net>
-
Alex Elder authored
The only time entries are added to or removed from the global rbd_dev_list is exactly when a "put" or "get" operation is being performed on a rbd_dev's id. So just move the list management code into get/put routines. Signed-off-by: Alex Elder <elder@dreamhost.com> Signed-off-by: Sage Weil <sage@newdream.net>
-
Alex Elder authored
The rbd_dev_list is just a simple list of all the current rbd_devices. Using the ctl_mutex as a concurrency guard is overkill. Instead, use a spinlock for that specific purpose. This also reduces the window that the ctl_mutex needs to be held in rbd_add(). Signed-off-by: Alex Elder <elder@dreamhost.com> Signed-off-by: Sage Weil <sage@newdream.net>
-
Alex Elder authored
In order to select a new unique identifier for an added rbd device, the list of all existing ones is searched and a value one greater than the highest id is used. The list search can be avoided by using an atomic variable that keeps track of the current highest id. Using a get/put model for id's we can limit the boundless growth of id numbers a bit by arranging to reuse the current highest id once it gets released. Add these calls to "put" the id when an rbd is getting removed. Note that this changes the pattern of device id's used--new values will never be below the highest one seen so far (even if there exists an unused lower one). I assert this is OK because the key property of an rbd id is its uniqueness, not its magnitude. Regardless, a follow-on patch will restore the old way of doing things, I just think this commit just makes the incremental change to atomics a little easier to understand. Signed-off-by: Alex Elder <elder@dreamhost.com> Signed-off-by: Sage Weil <sage@newdream.net>
-
Alex Elder authored
Move the loop that finds a new unique rbd id to use into its own helper function. Signed-off-by: Alex Elder <elder@dreamhost.com> Signed-off-by: Sage Weil <sage@newdream.net>
-
Josh Durgin authored
There's already a constant for this anyway. Since rbd_header_set_snap() is only used to set the rbd device snap_name field, just do that within that function rather than having it take the snap_name as an argument. Signed-off-by: Alex Elder <elder@dreamhost.com> Signed-off-by: Sage Weil <sage@newdream.net> v2: Changed interface rbd_header_set_snap() so it explicitly updates the snap_name in the rbd_device. Also added a BUILD_BUG_ON() to verify the size of the snap_name field is sufficient for SNAP_HEAD_NAME.
-
Alex Elder authored
The rbd_device structure maintains a duplicate copy of the ceph_client pointer maintained in its rbd_client structure. There appears to be no good reason for this, and its presence presents a risk of them getting out of synch or otherwise misused. So kill it off, and use the rbd_client copy only. Signed-off-by: Alex Elder <elder@dreamhost.com> Signed-off-by: Sage Weil <sage@newdream.net>
-
Alex Elder authored
ceph_parse_options() takes the address of a pointer as an argument and uses it to return the address of an allocated structure if successful. With this interface is not evident at call sites that the pointer is always initialized. Change the interface to return the address instead (or a pointer-coded error code) to make the validity of the returned pointer obvious. Signed-off-by: Alex Elder <elder@dreamhost.com> Signed-off-by: Sage Weil <sage@newdream.net>
-
Alex Elder authored
Some minor cleanups in "drivers/block/rbd.c: - Use the more meaningful "RBD_MAX_OBJ_NAME_LEN" in place if "96" in the definition of RBD_MAX_MD_NAME_LEN. - Use DEFINE_SPINLOCK() to define and initialize node_lock. - Drop a needless (char *) cast in parse_rbd_opts_token(). - Make a few minor formatting changes. Signed-off-by: Alex Elder <elder@dreamhost.com> Signed-off-by: Sage Weil <sage@newdream.net>
-
Alex Elder authored
This patch just rearranges a few bits of code to make more portions of ceph_setxattr() and ceph_removexattr() identical. Signed-off-by: Alex Elder <elder@dreamhost.com> Signed-off-by: Sage Weil <sage@newdream.net>
-
Alex Elder authored
All names defined in the directory and file virtual extended attribute tables are constant, and the size of each is known at compile time. So there's no need to compute their length every time any file's attribute is listed. Record the length of each string and use it when needed to determine the space need to represent them. In addition, compute the aggregate size of strings in each table just once at initialization time. Signed-off-by: Alex Elder <elder@dreamhost.com> Signed-off-by: Sage Weil <sage@newdream.net>
-
Alex Elder authored
The names of the callback functions used for virtual extended attributes are based only on the last component of the attribute name. Because of the way these are defined, this precludes allowing a single (lowest) attribute name for different callbacks, dependent on the type of file being operated on. (For example, it might be nice to support both "ceph.dir.layout" and "ceph.file.layout".) Just change the callback names to avoid this problem. Signed-off-by: Alex Elder <elder@dreamhost.com> Signed-off-by: Sage Weil <sage@newdream.net>
-
Alex Elder authored
A struct ceph_vxattr_cb does not represent a callback at all, but rather a virtual extended attribute itself. Drop the "_cb" suffix from its name to reflect that. Signed-off-by: Alex Elder <elder@dreamhost.com> Signed-off-by: Sage Weil <sage@newdream.net>
-
Alex Elder authored
Entries in the ceph virtual extended attribute tables all follow a distinct pattern in their definition. Enforce this pattern through the use of a macro. Also, a null name field signals the end of the table, so make that be the first field in the ceph_vxattr_cb structure. Signed-off-by: Alex Elder <elder@dreamhost.com> Signed-off-by: Sage Weil <sage@newdream.net>
-
Alex Elder authored
Use symbolic constants to define the top-level prefix for "ceph." extended attribute names. Signed-off-by: Alex Elder <elder@dreamhost.com> Signed-off-by: Sage Weil <sage@newdream.net>
-
Alex Elder authored
All callers of ceph_match_vxattr() determine what to pass as the first argument by calling ceph_inode_vxattrs(inode). Just do that inside ceph_match_vxattr() itself, changing it to take an inode rather than the vxattr pointer as its first argument. Also ensure the function works correctly for an empty table (i.e., containing only a terminating null entry). Signed-off-by: Alex Elder <elder@dreamhost.com> Signed-off-by: Sage Weil <sage@newdream.net>
-
Alex Elder authored
For some reason, ceph_setxattr() allocates an extra byte in which a '\0' is stored past the end of an extended attribute value. This is not needed, and is potentially misleading, so get rid of it. Signed-off-by: Alex Elder <elder@dreamhost.com> Signed-off-by: Sage Weil <sage@newdream.net>
-
Alex Elder authored
This fixes some spots where a type cast to (void *) was used as as a universal type hiding mechanism. Instead, properly cast the type to the intended target type. Signed-off-by: Alex Elder <elder@newdream.net> Signed-off-by: Sage Weil <sage@newdream.net>
-
Alex Elder authored
This eliminates type casts in some places where they are not required. Signed-off-by: Alex Elder <elder@newdream.net> Signed-off-by: Sage Weil <sage@newdream.net>
-
Alex Elder authored
A spinlock is used to protect a value used for selecting an array index for a string used for formatting a socket address for human consumption. The index is reset to 0 if it ever reaches the maximum index value. Instead, use an ever-increasing atomic variable as a sequence number, and compute the array index by masking off all but the sequence number's lowest bits. Make the number of entries in the array a power of two to allow the use of such a mask (to avoid jumps in the index value when the sequence number wraps). The length of these strings is somewhat arbitrarily set at 60 bytes. The worst-case length of a string produced is 54 bytes, for an IPv6 address that can't be shortened, e.g.: [1234:5678:9abc:def0:1111:2222:123.234.210.100]:32767 Change it so we arbitrarily use 64 bytes instead; if nothing else it will make the array of these line up better in hex dumps. Rename a few things to reinforce the distinction between the number of strings in the array and the length of individual strings. Signed-off-by: Alex Elder <elder@newdream.net> Signed-off-by: Sage Weil <sage@newdream.net>
-
Alex Elder authored
Rearrange ceph_tcp_connect() a bit, making use of "else" rather than re-testing a value with consecutive "if" statements. Don't record a connection's socket pointer unless the connect operation is successful. Signed-off-by: Alex Elder <elder@dreamhost.com> Signed-off-by: Sage Weil <sage@newdream.net>
-
Alex Elder authored
Each messenger allocates a page to be used when writing zeroes out in the event of error or other abnormal condition. Instead, use the kernel ZERO_PAGE() for that purpose. Signed-off-by: Alex Elder <elder@dreamhost.com> Signed-off-by: Sage Weil <sage@newdream.net>
-
Xi Wang authored
The overflow check for a + n * b should be (n > (ULONG_MAX - a) / b), rather than (n > ULONG_MAX / b - a). Signed-off-by: Xi Wang <xi.wang@gmail.com> Signed-off-by: Sage Weil <sage@newdream.net>
-
Xi Wang authored
The existing overflow check (n > ULONG_MAX / b) didn't work, because n = ULONG_MAX / b would both bypass the check and still overflow the allocation size a + n * b. The correct check should be (n > (ULONG_MAX - a) / b). Signed-off-by: Xi Wang <xi.wang@gmail.com> Signed-off-by: Sage Weil <sage@newdream.net>
-
Xi Wang authored
Return -EINVAL rather than panic if iinfo->symlink_len and inode->i_size do not match. Also use kstrndup rather than kmalloc/memcpy. Signed-off-by: Xi Wang <xi.wang@gmail.com> Reviewed-by: Alex Elder <elder@dreamhost.com>
-