- 23 Jan, 2018 1 commit
-
-
Hans de Goede authored
It is possible to have CONFIG_OF enabled on x86 builds, where we have no firmware provided max17042_platform_data. The CONFIG_OF implementation of max17042_get_pdata would return NULL in this case, causing the probe to fail. Instead always fallback to the default platform-data, as used on x86 sofar, when there is no firmware provided pdata, independent of CONFIG_OF. Signed-off-by: Hans de Goede <hdegoede@redhat.com> Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.co.uk>
-
- 22 Jan, 2018 1 commit
-
-
Hans de Goede authored
Even though the system is supplied, it may still be discharging if the supply is e.g. only delivering 5V 0.5A. Check the avg battery current if available for more accurate status reporting. Cc: James <kernel@madingley.org> Suggested-by: James <kernel@madingley.org> Signed-off-by: Hans de Goede <hdegoede@redhat.com> Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.co.uk>
-
- 09 Jan, 2018 4 commits
-
-
Hans de Goede authored
Add an entry for the AXP288 PMIC drivers with myself as maintainer. Signed-off-by: Hans de Goede <hdegoede@redhat.com> Acked-by: Chen-Yu Tsai <wens@csie.org> Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.co.uk>
-
Hans de Goede authored
The Intel Compute Stick (Cherry Trail version) and the Meegopad T08 HDMI stick, both use an axp288 PMIC. They also both have this wired up in such a way that the detection logic in the PMIC claims that a valid battery is present, resuling in GNOME and KDE showing a full-battery in their status bar and power-settings, while these devices do not have a battery. For lack of a better fix add a DMI blacklist and do not register the axp288_fuel_gauge psy on devices on the blacklist. Reviewed-by: Chen-Yu Tsai <wens@csie.org> Signed-off-by: Hans de Goede <hdegoede@redhat.com> Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.co.uk>
-
Hans de Goede authored
First check the discharge current, and when that is non 0 use that without also checking the charge current (which will be 0 then). This makes get_current() do only 1 i2c read instead of 2 when on battery. This is esp. important given the pmic i2c bus mutex stuff used on boards with an axp288 because the SoC's own punit also may access the axp288, which makes i2c accesses more expensive then normal. Signed-off-by: Hans de Goede <hdegoede@redhat.com> Reviewed-by: Chen-Yu Tsai <wens@csie.org> Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.co.uk>
-
Hans de Goede authored
Relying on the (dis)charge current reporting for reporting FULL back to userspace does not work really well and often leads to the reported status getting stuck at e.g. 98/99% (the fuelgauge is not perfect) for hours. What happens is that when the battery is full the axp288 keeps charging it with a very low current. Until it is really really full and once really really full, some inaccuracies in the adc lead to it then sometimes reporting a small discharging rate, even though an external pwr source is used. So we end up with a status of "charging" for hours after the battery is actually already full and sometimes this then flip-flops to discharging. This commit fixes this by first checking if a valid Vbus is present and if it is present using the fuel-gauge's reported percentage to check for a full battery. This commit also changes how get_status() determines if the battery is charging or discharging when not reporting it as full. We still use the current direction for this, but instead of reading 4 extra registers for this (2 16 bit regs), simplify things by using the current-direction bit in the power-status register, which already gets read anyways. This also reduces the amount of i2c reads to 1 when on battery and 2 when a valid Vbus is present. Signed-off-by: Hans de Goede <hdegoede@redhat.com> Reviewed-by: Chen-Yu Tsai <wens@csie.org> Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.co.uk>
-
- 08 Jan, 2018 17 commits
-
-
Julia Lawall authored
This driver creates a const structure that it stores in the data field of an of_device_id array. Add const to the declaration of the location that receives a value from the data field to ensure that the compiler will continue to check that the value is not modified and remove the const-dropping cast on the access to the data field. Done using Coccinelle. Signed-off-by: Julia Lawall <Julia.Lawall@lip6.fr> Acked-by: Alexandre Belloni <alexandre.belloni@free-electrons.com> Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.co.uk>
-
Julia Lawall authored
This driver creates two const structures that it stores in the data field of an of_device_id array. The data field of an of_device_id structure has type const void *, so there is no need for a const-discarding cast when putting const values into such a structure. Furthermore, adding const to the declaration of the location that receives a const value from such a field ensures that the compiler will continue to check that the value is not modified. The const-discarding cast on the extraction from the data field is thus no longer needed. Done using Coccinelle. Signed-off-by: Julia Lawall <Julia.Lawall@lip6.fr> Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.co.uk>
-
Pavel Machek authored
Simplify function that should be trivial. Signed-off-by: Pavel machek <pavel@ucw.cz> Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.co.uk>
-
Hans de Goede authored
Get iio-channels once during boot, delaying the probe if the axp288_adc drivers has not loaded yet, instead of getting them on demand each time we need them. This fixes the following errors in dmesg: axp288_fuel_gauge axp288_fuel_gauge: ADC charge current read failed:-19 Which were caused by the ondemand iio-channel read code not finding the channel when the axp288_adc driver had not loaded yet. Reviewed-by: Chen-Yu Tsai <wens@csie.org> Signed-off-by: Hans de Goede <hdegoede@redhat.com> Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.co.uk>
-
Hans de Goede authored
Properly stop any work we may have queued on probe-errors / remove. Rather then adding a remove driver callback for this, and goto style error handling to probe, use a devm_action for this. The devm_action gets registered before we register any of the extcon notifiers which may queue the work, devm does cleanup in reverse order, so this ensures that the notifiers are removed before we cancel the work. Reviewed-by: Chen-Yu Tsai <wens@csie.org> Signed-off-by: Hans de Goede <hdegoede@redhat.com> Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.co.uk>
-
Hans de Goede authored
Simplify extcon cable handling using the new devm_extcon_register_notifier_all function to listen to all cables in one go. Reviewed-by: Chen-Yu Tsai <wens@csie.org> Signed-off-by: Hans de Goede <hdegoede@redhat.com> Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.co.uk>
-
Hans de Goede authored
Use the right property for the input current limit and make it writable. Reviewed-by: Chen-Yu Tsai <wens@csie.org> Signed-off-by: Hans de Goede <hdegoede@redhat.com> Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.co.uk>
-
Hans de Goede authored
The code before this commit would pick 900 mA when asking for an input current limit of 600mA, rather then 500 mA, not good. While touching almost all code using the silly xxxMA defines anyways, also get rid of these simply typing out the numbers and switch the unit to uA as that is the psy class standard unit for currents. Reviewed-by: Chen-Yu Tsai <wens@csie.org> Signed-off-by: Hans de Goede <hdegoede@redhat.com> Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.co.uk>
-
Hans de Goede authored
The hardware may change this underneath us. Reviewed-by: Chen-Yu Tsai <wens@csie.org> Signed-off-by: Hans de Goede <hdegoede@redhat.com> Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.co.uk>
-
Hans de Goede authored
Now that we use regmap to do read-modify-write ops everywhere, we can rely on the regmap lock and no longer need our own lock. Reviewed-by: Chen-Yu Tsai <wens@csie.org> Signed-off-by: Hans de Goede <hdegoede@redhat.com> Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.co.uk>
-
Hans de Goede authored
Use regmap_update_bits in axp288_charger_set_vbus_inlmt, instead of DIY code. Reviewed-by: Chen-Yu Tsai <wens@csie.org> Signed-off-by: Hans de Goede <hdegoede@redhat.com> Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.co.uk>
-
Hans de Goede authored
While we are doing cleanups, also remove some double blank lines. Reviewed-by: Chen-Yu Tsai <wens@csie.org> Signed-off-by: Hans de Goede <hdegoede@redhat.com> Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.co.uk>
-
Hans de Goede authored
The extcon code is the only one to trigger our worker (outside of the initial run) and we can rely on it to only call us if things have changed, so there is no need to track the charger-enabled state. Reviewed-by: Chen-Yu Tsai <wens@csie.org> Signed-off-by: Hans de Goede <hdegoede@redhat.com> Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.co.uk>
-
Hans de Goede authored
Add missing (terminating) "\n"-s to some dev_dbg messages. Reviewed-by: Chen-Yu Tsai <wens@csie.org> Signed-off-by: Hans de Goede <hdegoede@redhat.com> Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.co.uk>
-
Hans de Goede authored
Before this commit we were relying solely on the extcon interface for cable detection, including to determine if a cable providing vbus is connected at all. This caused us to turn off charging at boot, because when we run the initial state processing the axp288-extcon driver is still running charger-type detection most of the time, so all charger cable types read as disconnected when we run the initial state processing. This commit reworks the axp288_charger_extcon_evt_worker flow to use the VBUS_VALID bit from the PWR_INPUT_STATUS register to determine if we should turn charging on/off. Note this is the same bit as we use for the online property. If VBUS_VALID is set, but the extcon code has not completed the charger type detection yet, we now simply bail leaving things as configured by the BIOS (we will get a notifier call when the extcon code is done and reschedule the axp288_charger_extcon_evt_worker). The extcon code is the only one to trigger the worker (outside of the initial run) and we can rely on it to only call us if things have changed, so while we are completely refactoring axp288_charger_extcon_evt_worker, also remove the code to check if the state has changed. Reviewed-by: Chen-Yu Tsai <wens@csie.org> Signed-off-by: Hans de Goede <hdegoede@redhat.com> Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.co.uk>
-
Dong Aisheng authored
There's no user of it in kernel now and it basically functions the same as the generic syscon-poweroff.c to which we have already switched. So let's remove it. Cc: Robin Gong <yibin.gong@nxp.com> Cc: Shawn Guo <shawnguo@kernel.org> Signed-off-by: Dong Aisheng <aisheng.dong@nxp.com> Acked-by: Rob Herring <robh@kernel.org> Reviewed-by: Fabio Estevam <fabio.estevam@nxp.com> Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.co.uk>
-
Bjorn Andersson authored
When PSHOLD in a Qualcomm platform is deasserted the PMIC will perform either a power off or a restart of the system. The action to take is configured in the PON block, which is controlled by a separate driver. As the configuration logic was added to the pm8941-pwrkey driver the comment in do_msm_poweroff() is no longer valid and the name do_msm_restart() is misleading. Update the naming and drop the comment. Signed-off-by: Bjorn Andersson <bjorn.andersson@linaro.org> Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.co.uk>
-
- 08 Dec, 2017 1 commit
-
-
Pavel Machek authored
This adds basic support for BQ27521 battery monitor, used in Nokia N9 and N950. In particular, battery voltage is important to be able to tell when the battery is almost empty. Emptying battery on N950 is pretty painful, as flasher needs to be used to recover phone in such case. Signed-off-by: Pavel Machek <pavel@ucw.cz> Acked-by: Andrew F. Davis <afd@ti.com> Acked-by: Rob Herring <robh@kernel.org> Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.co.uk>
-
- 01 Dec, 2017 9 commits
-
-
Hans de Goede authored
Now that drivers/i2c/busses/i2c-cht-wc.c uses "input-current-limit-from-supplier" instead of "extcon-name" the last user of the bq24190 extcon code is gone, remove it. Signed-off-by: Hans de Goede <hdegoede@redhat.com> Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.co.uk>
-
Mike Looijmans authored
The driver sets the fuel gauge to continuous monitoring on startup, for the models that support this. When the board shuts down, the chip remains in that mode, causing a few mA drain on the battery every 2 or 10 seconds. This patch registers a shutdown handler that turns off the monitoring to prevent this battery drain. Signed-off-by: Mike Looijmans <mike.looijmans@topic.nl> Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.co.uk>
-
Sebastian Reichel authored
Merge fixes for 4.15-rc phase into next branch. Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.co.uk>
-
Arvind Yadav authored
The platform_get_irq_byname() function returns -1 if an error occurs. zero or positive number on success. platform_get_irq_byname() error checking for zero is not correct. Signed-off-by: Arvind Yadav <arvind.yadav.cs@gmail.com> Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.co.uk>
-
Christophe JAILLET authored
If an error occurs when we enable the backup battery charging, we should go through the error handling path directly. Before commit db43e6c4 ("ab8500-bm: Add usb power path support") this was the case, but this commit has added some code between the last test and the 'out' label. So, in case of error, this added code is executed and the error may be silently ignored. Fix it by adding the missing 'goto out', as done in all other error handling paths. Fixes: db43e6c4 ("ab8500-bm: Add usb power path support") Signed-off-by: Christophe JAILLET <christophe.jaillet@wanadoo.fr> Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.co.uk>
-
Christophe JAILLET authored
'ret' is know to be 0 at this point, because it has not been updated by the the previous call to 'abx500_mask_and_set_register_interruptible()'. Fix it by updating 'ret' before checking if an error occurred. Fixes: 84edbeea ("ab8500-charger: AB8500 charger driver") Signed-off-by: Christophe JAILLET <christophe.jaillet@wanadoo.fr> Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.co.uk>
-
Ryosuke Saito authored
Should be discharging_max_duration_ms, not charging_max_duration_ms. Signed-off-by: Ryosuke Saito <raitosyo@gmail.com> Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.co.uk>
-
Jesse Chan authored
This change resolves a new compile-time warning when built as a loadable module: WARNING: modpost: missing MODULE_LICENSE() in drivers/power/reset/zx-reboot.o see include/linux/module.h for more information This adds the license as "GPL v2", which matches the header of the file. MODULE_DESCRIPTION and MODULE_AUTHOR are also added. Signed-off-by: Jesse Chan <jc@linux.com> Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.co.uk>
-
Dan Carpenter authored
The original code does this: "1 << (1 << 11)" which is undefined in C. Fixes: dbc4deda ("power: Adds support for Smart Battery System Manager") Signed-off-by: Dan Carpenter <dan.carpenter@oracle.com> Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.co.uk>
-
- 27 Nov, 2017 1 commit
-
-
Linus Torvalds authored
-
- 26 Nov, 2017 6 commits
-
-
git://git.armlinux.org.uk/~rmk/linux-armLinus Torvalds authored
Pull ARM fixes from Russell King: - LPAE fixes for kernel-readonly regions - Fix for get_user_pages_fast on LPAE systems - avoid tying decompressor to a particular platform if DEBUG_LL is enabled - BUG if we attempt to return to userspace but the to-be-restored PSR value keeps us in privileged mode (defeating an issue that ftracetest found) * 'fixes' of git://git.armlinux.org.uk/~rmk/linux-arm: ARM: BUG if jumping to usermode address in kernel mode ARM: 8722/1: mm: make STRICT_KERNEL_RWX effective for LPAE ARM: 8721/1: mm: dump: check hardware RO bit for LPAE ARM: make decompressor debug output user selectable ARM: fix get_user_pages_fast
-
git://git.kernel.org/pub/scm/linux/kernel/git/tip/tipLinus Torvalds authored
Pull irq fixes from Thomas Glexiner: - unbreak the irq trigger type check for legacy platforms - a handful fixes for ARM GIC v3/4 interrupt controllers - a few trivial fixes all over the place * 'irq-urgent-for-linus' of git://git.kernel.org/pub/scm/linux/kernel/git/tip/tip: genirq/matrix: Make - vs ?: Precedence explicit irqchip/imgpdc: Use resource_size function on resource object irqchip/qcom: Fix u32 comparison with value less than zero irqchip/exiu: Fix return value check in exiu_init() irqchip/gic-v3-its: Remove artificial dependency on PCI irqchip/gic-v4: Add forward definition of struct irq_domain_ops irqchip/gic-v3: pr_err() strings should end with newlines irqchip/s3c24xx: pr_err() strings should end with newlines irqchip/gic-v3: Fix ppi-partitions lookup irqchip/gic-v4: Clear IRQ_DISABLE_UNLAZY again if mapping fails genirq: Track whether the trigger type has been set
-
git://git.kernel.org/pub/scm/linux/kernel/git/tip/tipLinus Torvalds authored
Pull misc x86 fixes from Ingo Molnar: - topology enumeration fixes - KASAN fix - two entry fixes (not yet the big series related to KASLR) - remove obsolete code - instruction decoder fix - better /dev/mem sanity checks, hopefully working better this time - pkeys fixes - two ACPI fixes - 5-level paging related fixes - UMIP fixes that should make application visible faults more debuggable - boot fix for weird virtualization environment * 'x86-urgent-for-linus' of git://git.kernel.org/pub/scm/linux/kernel/git/tip/tip: (24 commits) x86/decoder: Add new TEST instruction pattern x86/PCI: Remove unused HyperTransport interrupt support x86/umip: Fix insn_get_code_seg_params()'s return value x86/boot/KASLR: Remove unused variable x86/entry/64: Add missing irqflags tracing to native_load_gs_index() x86/mm/kasan: Don't use vmemmap_populate() to initialize shadow x86/entry/64: Fix entry_SYSCALL_64_after_hwframe() IRQ tracing x86/pkeys/selftests: Fix protection keys write() warning x86/pkeys/selftests: Rename 'si_pkey' to 'siginfo_pkey' x86/mpx/selftests: Fix up weird arrays x86/pkeys: Update documentation about availability x86/umip: Print a warning into the syslog if UMIP-protected instructions are used x86/smpboot: Fix __max_logical_packages estimate x86/topology: Avoid wasting 128k for package id array perf/x86/intel/uncore: Cache logical pkg id in uncore driver x86/acpi: Reduce code duplication in mp_override_legacy_irq() x86/acpi: Handle SCI interrupts above legacy space gracefully x86/boot: Fix boot failure when SMP MP-table is based at 0 x86/mm: Limit mmap() of /dev/mem to valid physical addresses x86/selftests: Add test for mapping placement for 5-level paging ...
-
git://git.kernel.org/pub/scm/linux/kernel/git/tip/tipLinus Torvalds authored
Pull scheduler fixes from Ingo Molnar: "Misc fixes: a documentation fix, a Sparse warning fix and a debugging fix" * 'sched-urgent-for-linus' of git://git.kernel.org/pub/scm/linux/kernel/git/tip/tip: sched/debug: Fix task state recording/printout sched/deadline: Don't use dubious signed bitfields sched/deadline: Fix the description of runtime accounting in the documentation
-
git://git.kernel.org/pub/scm/linux/kernel/git/tip/tipLinus Torvalds authored
Pull perf fixes from Ingo Molnar: "Misc fixes: two PMU driver fixes and a memory leak fix" * 'perf-urgent-for-linus' of git://git.kernel.org/pub/scm/linux/kernel/git/tip/tip: perf/core: Fix memory leak triggered by perf --namespace perf/x86/intel/uncore: Add event constraint for BDX PCU perf/x86/intel: Hide TSX events when RTM is not supported
-
git://git.kernel.org/pub/scm/linux/kernel/git/tip/tipLinus Torvalds authored
Pull static key fix from Ingo Molnar: "Fix a boot warning related to bad init ordering of the static keys self-test" * 'locking-urgent-for-linus' of git://git.kernel.org/pub/scm/linux/kernel/git/tip/tip: jump_label: Invoke jump_label_test() via early_initcall()
-