    • Viresh Kumar's avatar
      arm64: dts: hisilicon: Add missing cooling device properties for CPUs · 4d4585c2
      Viresh Kumar authored
      The cooling device properties, like "#cooling-cells" and
      "dynamic-power-coefficient", should either be present for all the CPUs
      of a cluster or none. If these are present only for a subset of CPUs of
      a cluster then things will start falling apart as soon as the CPUs are
      brought online in a different order. For example, this will happen
      because the operating system looks for such properties in the CPU node
      it is trying to bring up, so that it can register a cooling device.
      
      Add such missing properties.
      
      Do minor rearrangement as well to keep ordering consistent.
      Signed-off-by: default avatarViresh Kumar <viresh.kumar@linaro.org>
      Signed-off-by: default avatarWei Xu <xuwei5@hisilicon.com>