- 25 Jan, 2015 3 commits
-
-
Guenter Roeck authored
sun6i restart is now handled by its watchdog driver directly, so this driver is no longer needed. Signed-off-by: Guenter Roeck <linux@roeck-us.net> Acked-by: Maxime Ripard <maxime.ripard@free-electrons.com> Signed-off-by: Sebastian Reichel <sre@kernel.org>
-
Guenter Roeck authored
Register with kernel restart handler instead of setting arm_pm_restart directly. Register with high priority since the driver unconditionally overwrites other restart handlers if instantiated. Signed-off-by: Guenter Roeck <linux@roeck-us.net> Signed-off-by: Sebastian Reichel <sre@kernel.org>
-
Guenter Roeck authored
Register with kernel restart handler instead of setting arm_pm_restart directly. Select high priority since the restart handler is instantiated through devicetree, indicating that it should be used if configured. Signed-off-by: Guenter Roeck <linux@roeck-us.net> Signed-off-by: Sebastian Reichel <sre@kernel.org>
-
- 23 Jan, 2015 1 commit
-
-
Krzysztof Kozlowski authored
Replace hard-coded numbers for indices of power supply array with enum. This improves a little the readability as one does not have to guess which power supply is associated with number. Signed-off-by: Krzysztof Kozlowski <k.kozlowski@samsung.com> Signed-off-by: Sebastian Reichel <sre@kernel.org>
-
- 22 Jan, 2015 5 commits
-
-
Mike Looijmans authored
This adds the devicetree binding documentation for the LTC2941 and LTC2943 driver. These are I2C connected battery gas gauge ICs. Signed-off-by: Mike Looijmans <mike.looijmans@topic.nl> Signed-off-by: Sebastian Reichel <sre@kernel.org>
-
Mike Looijmans authored
Both the LTC2941 and LTC2943 measure battery capacity. The LTC2943 is compatible with the LTC2941, it adds voltage and temperature monitoring, and uses a slightly different conversion formula for the charge counter. To avoid confusion with e.g. the LTC2945, the driver is called LTC2941 instead of LTC294X. v2: Fix units of measurement: uV, uA and centidegrees. v3: Correctly set configuration register. Allow negative values for the sense resistor. v4: Run checkpatch.pl and fix all errors and warnings. v5: Prefix "lltc," to devicetree properties. Signed-off-by: Mike Looijmans <mike.looijmans@topic.nl> [ removed .owner field ] Signed-off-by: Sebastian Reichel <sre@kernel.org>
-
Kevin Cernekee authored
The register bit fields are a little different, so add an entry and a compatible string to accommodate them. Signed-off-by: Kevin Cernekee <cernekee@gmail.com> Signed-off-by: Sebastian Reichel <sre@kernel.org>
-
Kevin Cernekee authored
Some of the older chips used different bits to arm and trigger the reset. Add the infrastructure needed to specify this through the "compatible" string. Signed-off-by: Kevin Cernekee <cernekee@gmail.com> Signed-off-by: Sebastian Reichel <sre@kernel.org>
-
Kevin Cernekee authored
Now that the driver doesn't use any ARM-specific headers, it is safe to build on MIPS or with COMPILE_TEST. Signed-off-by: Kevin Cernekee <cernekee@gmail.com> Signed-off-by: Sebastian Reichel <sre@kernel.org>
-
- 21 Jan, 2015 11 commits
-
-
Jonghwa Lee authored
To guerantee proper charing and managing batteries even in suspend, charger-manager has used rtc device with rtc framework interface. However, it is better to use alarmtimer for cleaner and more appropriate operation. This patch makes driver to use alarmtimer for polling work in suspend and removes all deprecated codes related with using rtc interface. Signed-off-by: Jonghwa Lee <jonghwa3.lee@samsung.com> Signed-off-by: Sebastian Reichel <sre@kernel.org>
-
Guenter Roeck authored
at91_poweroff_get_wakeup_mode can return a negative error code and should therefore not return an enum type. Similar, its result should not be assigned to an enum type. Otherwise, the returned value is never negative, resulting in a compiler warning and a missed error condition, which in turn results in writing bad values into a chip register. Also fix other compiler warnings which can be easily avoided. drivers/power/reset/at91-poweroff.c:74:24: warning: type qualifiers ignored on function return type drivers/power/reset/at91-poweroff.c:74:24: warning: no previous prototype for 'at91_poweroff_get_wakeup_mode' drivers/power/reset/at91-poweroff.c:83:16: warning: comparison between signed and unsigned integer expressions drivers/power/reset/at91-poweroff.c:97:2: warning: comparison of unsigned expression < 0 is always false Cc: Maxime Ripard <maxime.ripard@free-electrons.com> Cc: Nicolas Ferre <nicolas.ferre@atmel.com> Signed-off-by: Guenter Roeck <linux@roeck-us.net> Acked-by: Maxime Ripard <maxime.ripard@free-electrons.com> Signed-off-by: Sebastian Reichel <sre@kernel.org>
-
Puthikorn Voravootivat authored
In current driver, power_supply_changed() is called whenever any of the battery attribute changed. This causes kernel to increases the '/sys/power/wakeup_count' and make suspend not working correctly. This patch change this behavior to call power_supply_changed() only when the battery capacity changed. Signed-off-by: Puthikorn Voravootivat <puthik@chromium.org> Reviewed-by: David Riley <davidriley@chromium.org> Reviewed-by: Benson Leung <bleung@chromium.org> Signed-off-by: Sebastian Reichel <sre@kernel.org>
-
Eric Bénard authored
- SOC is at 0x1C so we must add 0x4 as stated in the comment to read the right value. - DCAP is at 0x3c so we also must use a value with the right offset to get the correct design capacity. Actually testing on a bq27410 which has the same register map as bq27425 (but adds new registers). Signed-off-by: Eric Bénard <eric@eukrea.com> Signed-off-by: Sebastian Reichel <sre@kernel.org>
-
Karol Wrona authored
This is only a small clean-up. The driver can be built without SYSFS as there exist stubs for used functions. Signed-off-by: Karol Wrona <k.wrona@samsung.com> Reviewed-by: Krzysztof Kozlowski <k.kozlowski@samsung.com> Signed-off-by: Sebastian Reichel <sre@kernel.org>
-
Lad, Prabhakar authored
This patch fixes following build warning: In file included from include/linux/printk.h:261:0, from include/linux/kernel.h:13, from include/linux/list.h:8, from include/linux/module.h:9, from drivers/power/bq24190_charger.c:11: drivers/power/bq24190_charger.c: In function ‘bq24190_irq_handler_thread’: include/linux/dynamic_debug.h:86:20: warning: ‘ss_reg’ may be used uninitialized in this function [-Wmaybe-uninitialized] __dynamic_dev_dbg(&descriptor, dev, fmt, \ ^ drivers/power/bq24190_charger.c:1211:5: note: ‘ss_reg’ was declared here u8 ss_reg, f_reg; ^ In file included from include/linux/printk.h:261:0, from include/linux/kernel.h:13, from include/linux/list.h:8, from include/linux/module.h:9, from drivers/power/bq24190_charger.c:11: include/linux/dynamic_debug.h:86:20: warning: ‘f_reg’ may be used uninitialized in this function [-Wmaybe-uninitialized] __dynamic_dev_dbg(&descriptor, dev, fmt, \ ^ drivers/power/bq24190_charger.c:1211:13: note: ‘f_reg’ was declared here u8 ss_reg, f_reg; Signed-off-by: Lad, Prabhakar <prabhakar.csengg@gmail.com> Signed-off-by: Sebastian Reichel <sre@kernel.org>
-
Geert Uytterhoeven authored
Add a reset driver for Renesas R-Mobile and SH-Mobile SoCs. It registers a restart handler to trigger a soft power-on reset through the R-Mobile System Controller. The priority of this restart handler is 192, to allow a watchdog driver to use priority 128. Note that we do not use syscon-reboot, as the HPB (Peripheral Bus Bridge) semaphore should be acquired on systems where both the ARM and SH core are in use. The driver can be extended later to support this, when needed. Signed-off-by: Geert Uytterhoeven <geert+renesas@glider.be> Reviewed-by: Guenter Roeck <linux@roeck-us.net> Signed-off-by: Sebastian Reichel <sre@kernel.org>
-
Rickard Strandqvist authored
Remove the function ab8500_fg_reinit() that is not used anywhere. This was partially found by using a static code analysis program called cppcheck. Signed-off-by: Rickard Strandqvist <rickard_strandqvist@spectrumdigital.se> Acked-by: Arnd Bergmann <arnd@arndb.de> Signed-off-by: Sebastian Reichel <sre@kernel.org>
-
kbuild test robot authored
drivers/power/max77693_charger.c:747:3-8: No need to set .owner here. The core will do it. Remove .owner field if calls are used which set it automatically Generated by: scripts/coccinelle/api/platform_no_drv_owner.cocci CC: Krzysztof Kozlowski <k.kozlowski@samsung.com> Signed-off-by: Fengguang Wu <fengguang.wu@intel.com> Reviewed-by: Krzysztof Kozlowski <k.kozlowski@samsung.com> Signed-off-by: Sebastian Reichel <sre@kernel.org>
-
kbuild test robot authored
drivers/power/max77693_charger.c:615:1-4: WARNING: end returns can be simpified Simplify a trivial if-return sequence. Possibly combine with a preceding function call. Generated by: scripts/coccinelle/misc/simple_return.cocci CC: Krzysztof Kozlowski <k.kozlowski@samsung.com> Signed-off-by: Fengguang Wu <fengguang.wu@intel.com> Reviewed-by: Krzysztof Kozlowski <k.kozlowski@samsung.com> Signed-off-by: Sebastian Reichel <sre@kernel.org>
-
Pawel Moll authored
Now, as all VE platforms have to be booted with DT, the code handling non-DT case can be removed. Signed-off-by: Pawel Moll <pawel.moll@arm.com> Signed-off-by: Sebastian Reichel <sre@kernel.org>
-
- 20 Jan, 2015 20 commits
-
-
Krzysztof Kozlowski authored
Add myself as supporter to help in reviewing patches for Maxim 14577 and 77693 MUIC charger drivers. These are used on Exynos-based boards (Trats 2, Gear 1 and Gear 2). Signed-off-by: Krzysztof Kozlowski <k.kozlowski@samsung.com> Cc: Sebastian Reichel <sre@kernel.org> Cc: Dmitry Eremin-Solenikov <dbaryshkov@gmail.com> Cc: David Woodhouse <dwmw2@infradead.org> Acked-By: Sebastian Reichel <sre@kernel.org> Signed-off-by: Sebastian Reichel <sre@kernel.org>
-
Krzysztof Kozlowski authored
Document the settings exported by max77693 charger driver through sysfs entries: - fast_charge_timer - top_off_threshold_current - top_off_timer Signed-off-by: Krzysztof Kozlowski <k.kozlowski@samsung.com> Signed-off-by: Sebastian Reichel <sre@kernel.org>
-
Krzysztof Kozlowski authored
Add new driver for Maxim 77693 switch-mode charger (part of max77693 MFD driver) providing power supply class information to userspace. The charger has +20V tolerant input. Current input can be set from 0 to 2.58 A. The charger can deliver up to 2.1 A to the battery or 3.5 A to the system (when supplying additional current from battery to system). The driver is configured through DTS (battery and system related settings) and sysfs entries (timers and top-off charging threshold). Signed-off-by: Krzysztof Kozlowski <k.kozlowski@samsung.com> Signed-off-by: Sebastian Reichel <sre@kernel.org>
-
Krzysztof Kozlowski authored
Prepare for adding support for Maxim 77693 charger by adding necessary new defines. Signed-off-by: Krzysztof Kozlowski <k.kozlowski@samsung.com> Acked-by: Lee Jones <lee.jones@linaro.org> Signed-off-by: Sebastian Reichel <sre@kernel.org>
-
Krzysztof Kozlowski authored
Document new device tree bindings for Maxim 77693 charger driver. Signed-off-by: Krzysztof Kozlowski <k.kozlowski@samsung.com> Signed-off-by: Sebastian Reichel <sre@kernel.org>
-
Krzysztof Kozlowski authored
The regmap_config struct may be const because it is not modified by the driver and regmap_init() accepts pointer to const. Signed-off-by: Krzysztof Kozlowski <k.kozlowski@samsung.com> Signed-off-by: Sebastian Reichel <sre@kernel.org>
-
Krzysztof Kozlowski authored
The driver mismatched 'num_supplicants' with 'num_supplies' of power_supply structure. It provided list of supplicants (power_supply.supplied_to) but did not set the number of supplicants. Instead it set the num_supplies which is used when iterating over number of supplies (power_supply.supplied_from). As a result the list of supplicants was ignored by core because its size was 0. Signed-off-by: Krzysztof Kozlowski <k.kozlowski@samsung.com> Cc: <stable@vger.kernel.org> Fixes: d7bf353f ("bq24190_charger: Add support for TI BQ24190 Battery Charger") Signed-off-by: Sebastian Reichel <sre@kernel.org>
-
Dmitry Eremin-Solenikov authored
Teach collie_battery driver to communicate to the kernel that it can generate wakeup events. Handle enabling/disabling wakeup on battery full event in suspend/resume callbacks. Signed-off-by: Dmitry Eremin-Solenikov <dbaryshkov@gmail.com> Signed-off-by: Sebastian Reichel <sre@kernel.org>
-
Dmitry Eremin-Solenikov authored
enable_irq_wakeup returns 0 in case it correctly enabled the IRQ to generate the wakeup event (and thus resume should call disable_irq_wake). Currently gpio-charger driver has this logic inverted. Correct that thus correcting enable/disable_irq_wake() calls balance. Cc: stable@vger.kernel.org Signed-off-by: Dmitry Eremin-Solenikov <dbaryshkov@gmail.com> Signed-off-by: Sebastian Reichel <sre@kernel.org>
-
Beomho Seo authored
This patch adds device driver of Richtek PMIC. The driver support battery fuel gauge. Fuel gauge calculates and determines the battery state of charge (SOC) according to battery open circuit voltage (OCV). Also, this driver provides battery average voltage, voltage and battery present property. Cc: Sebastian Reichel <sre@kernel.org> Cc: Dmitry Eremin-Solenikov <dbaryshkov@gmail.com> Cc: David Woodhouse <dwmw2@infradead.org> Signed-off-by: Beomho Seo <beomho.seo@samsung.com> Acked-by: Chanwoo Choi <cw00.choi@samsung.com> Signed-off-by: Sebastian Reichel <sre@kernel.org>
-
Frans Klaver authored
Document the fact that the trigger signal is now optional, and describe the behavior when this is used. While at it, fix a typo, and paraphrase a sentence to be less platform specific. Signed-off-by: Frans Klaver <frans.klaver@xsens.com> Signed-off-by: Sebastian Reichel <sre@kernel.org>
-
Frans Klaver authored
Currently the ltc2952 supports only one button sequence to initiate powerdown. This is not always desirable, as even prolonged button presses can happen in use. Allow ltc2952 users to pick their own power down sequence, by making the trigger input optional. Since this still means that the ltc2952 may power down the platform if the power button is pressed for about 5 seconds, we still need to make sure to start the watchdog toggle to prolong the system power for as long as we need it. This will still allow the system to control power using the kill signal. Signed-off-by: Frans Klaver <frans.klaver@xsens.com> Signed-off-by: Sebastian Reichel <sre@kernel.org>
-
Frans Klaver authored
In ltc2952_poweroff_handler it is theoretically possible that the timer fails to start on first pass (button press), but succeeds in starting on the second (button release). This will cause the button press to be misinterpreted, and will incorrectly shut down the system. Because a picture says more than a thousand words: Expected behavior: tmr: ++++++++++ btn: -----__________----- Faulty behavior: tmr: +++++ btn: -----__________----- Legend: + timer runs _ button pressed - button depressed To prevent this from happening, check the value of the gpio before starting the timer. If the button is active, we should start the timer, else we should stop it. The situation described can now still occur if the polarity of the input pin is set incorrectly, but that at least is predictable behavior and can be detected during the first tests. Signed-off-by: Frans Klaver <frans.klaver@xsens.com> Signed-off-by: Sebastian Reichel <sre@kernel.org>
-
Frans Klaver authored
Disable the timers when ltc2952_poweroff is removed. We don't want to risk calling functions on data that no longer exist. Signed-off-by: Frans Klaver <frans.klaver@xsens.com> Signed-off-by: Sebastian Reichel <sre@kernel.org>
-
Frans Klaver authored
The function pointers for the timers and pm_power_off are assigned with C++ style foo = &func; Let's change it instead to the more C style foo = func; Signed-off-by: Frans Klaver <frans.klaver@xsens.com> Signed-off-by: Sebastian Reichel <sre@kernel.org>
-
Frans Klaver authored
ltc2952_poweroff_handler uses gotos to return from the function. Since we don't do cleanups exiting this function, just return IRQ_HANDLED on the spot and be done with it. While at it, remove the variable 'ret'. It was never used very much. Signed-off-by: Frans Klaver <frans.klaver@xsens.com> Signed-off-by: Sebastian Reichel <sre@kernel.org>
-
Frans Klaver authored
Documentation/SubmittingDrivers suggests these be implemented even when they do nothing. On the other hand, the platform code calls these functions 'legacy'. Suspend and resume operations should go into a pm_ops structure, pointed at by the driver's pm field. This approach would lead to a lot of boiler plate, while achieving nothing. Drop the functions instead. Signed-off-by: Frans Klaver <frans.klaver@xsens.com> Signed-off-by: Sebastian Reichel <sre@kernel.org>
-
Frans Klaver authored
As per Documentation/CodingStyle ch.4, we should keep global variables to a mininum. Move the panic state into the driver data, regardless of whether panic is a system state or not. This removes the need for the custom _init and _exit functions, so replace them with a call to the module_platform_driver() macro. Signed-off-by: Frans Klaver <frans.klaver@xsens.com> Signed-off-by: Sebastian Reichel <sre@kernel.org>
-
Frans Klaver authored
Documentation/CodingStyle ch.4 mentions in a side node that global variables should only be used if you really need them. Reduce the use of the global instance of ltc2952_poweroff so we may eventually remove it entirely. While at it, rename ltc2952_poweroff_data to ltc2952_poweroff, just to save that little bit of typing. Signed-off-by: Frans Klaver <frans.klaver@xsens.com> Signed-off-by: Sebastian Reichel <sre@kernel.org>
-
Frans Klaver authored
This reduces cleanup code and chance of errors. Signed-off-by: Frans Klaver <frans.klaver@xsens.com> Signed-off-by: Sebastian Reichel <sre@kernel.org>
-