Commit ae47e257 authored by Joerg Bruehe's avatar Joerg Bruehe

Automerge the fix for bug#27072 into 5.1-bugteam

parents d2e58e4e b3eac87c
# Copyright (C) 2000-2008 MySQL AB, 2008-2010 Sun Microsystems, Inc. # Copyright (c) 2000, 2010, Oracle and/or its affiliates. All rights reserved.
# #
# This program is free software; you can redistribute it and/or modify # This program is free software; you can redistribute it and/or modify
# it under the terms of the GNU General Public License as published by # it under the terms of the GNU General Public License as published by
...@@ -610,6 +610,7 @@ touch $RBR%{_sysconfdir}/mysqlmanager.passwd ...@@ -610,6 +610,7 @@ touch $RBR%{_sysconfdir}/mysqlmanager.passwd
############################################################################## ##############################################################################
%pre server %pre server
mysql_datadir=%{mysqldatadir}
# Check if we can safely upgrade. An upgrade is only safe if it's from one # Check if we can safely upgrade. An upgrade is only safe if it's from one
# of our RPMs in the same version family. # of our RPMs in the same version family.
...@@ -678,7 +679,74 @@ HERE ...@@ -678,7 +679,74 @@ HERE
fi fi
fi fi
# We assume that if there is exactly one ".pid" file,
# it contains the valid PID of a running MySQL server.
NR_PID_FILES=`ls $mysql_datadir/*.pid 2>/dev/null | wc -l`
case $NR_PID_FILES in
0 ) SERVER_TO_START='' ;; # No "*.pid" file == no running server
1 ) SERVER_TO_START='true' ;;
* ) SERVER_TO_START='' # Situation not clear
SEVERAL_PID_FILES=true ;;
esac
# That logic may be debated: We might check whether it is non-empty,
# contains exactly one number (possibly a PID), and whether "ps" finds it.
# OTOH, if there is no such process, it means a crash without a cleanup -
# is that a reason not to start a new server after upgrade?
STATUS_FILE=$mysql_datadir/RPM_UPGRADE_MARKER
if [ -f $STATUS_FILE ]; then
echo "Some previous upgrade was not finished:"
ls -ld $STATUS_FILE
echo "Please check its status, then do"
echo " rm $STATUS_FILE"
echo "before repeating the MySQL upgrade."
exit 1
elif [ -n "$SEVERAL_PID_FILES" ] ; then
echo "Your MySQL directory '$mysql_datadir' has more than one PID file:"
ls -ld $mysql_datadir/*.pid
echo "Please check which one (if any) corresponds to a running server"
echo "and delete all others before repeating the MySQL upgrade."
exit 1
fi
NEW_VERSION=%{mysql_version}-%{release}
# The "pre" section code is also run on a first installation,
# when there is no data directory yet. Protect against error messages.
if [ -d $mysql_datadir ] ; then
echo "MySQL RPM upgrade to version $NEW_VERSION" > $STATUS_FILE
echo "'pre' step running at `date`" >> $STATUS_FILE
echo >> $STATUS_FILE
echo "ERR file(s):" >> $STATUS_FILE
ls -ltr $mysql_datadir/*.err >> $STATUS_FILE
echo >> $STATUS_FILE
echo "Latest 'Version' line in latest file:" >> $STATUS_FILE
grep '^Version' `ls -tr $mysql_datadir/*.err | tail -1` | \
tail -1 >> $STATUS_FILE
echo >> $STATUS_FILE
if [ -n "$SERVER_TO_START" ] ; then
# There is only one PID file, race possibility ignored
echo "PID file:" >> $STATUS_FILE
ls -l $mysql_datadir/*.pid >> $STATUS_FILE
cat $mysql_datadir/*.pid >> $STATUS_FILE
echo >> $STATUS_FILE
echo "Server process:" >> $STATUS_FILE
ps -fp `cat $mysql_datadir/*.pid` >> $STATUS_FILE
echo >> $STATUS_FILE
echo "SERVER_TO_START=$SERVER_TO_START" >> $STATUS_FILE
else
# Take a note we checked it ...
echo "PID file:" >> $STATUS_FILE
ls -l $mysql_datadir/*.pid >> $STATUS_FILE 2>&1
fi
fi
# Shut down a previously installed server first # Shut down a previously installed server first
# Note we *could* make that depend on $SERVER_TO_START, but we rather don't,
# so a "stop" is attempted even if there is no PID file.
# (Maybe the "stop" doesn't work then, but we might fix that in itself.)
if [ -x %{_sysconfdir}/init.d/mysql ] ; then if [ -x %{_sysconfdir}/init.d/mysql ] ; then
%{_sysconfdir}/init.d/mysql stop > /dev/null 2>&1 %{_sysconfdir}/init.d/mysql stop > /dev/null 2>&1
echo "Giving mysqld 5 seconds to exit nicely" echo "Giving mysqld 5 seconds to exit nicely"
...@@ -687,17 +755,33 @@ fi ...@@ -687,17 +755,33 @@ fi
%post server %post server
mysql_datadir=%{mysqldatadir} mysql_datadir=%{mysqldatadir}
NEW_VERSION=%{mysql_version}-%{release}
STATUS_FILE=$mysql_datadir/RPM_UPGRADE_MARKER
# ---------------------------------------------------------------------- # ----------------------------------------------------------------------
# Create data directory if needed # Create data directory if needed, check whether upgrade or install
# ---------------------------------------------------------------------- # ----------------------------------------------------------------------
if [ ! -d $mysql_datadir ] ; then mkdir -m 755 $mysql_datadir; fi if [ ! -d $mysql_datadir ] ; then mkdir -m 755 $mysql_datadir; fi
if [ ! -d $mysql_datadir/mysql ] ; then mkdir $mysql_datadir/mysql; fi if [ -f $STATUS_FILE ] ; then
SERVER_TO_START=`grep '^SERVER_TO_START=' $STATUS_FILE | cut -c17-`
else
SERVER_TO_START='true' # This is for 5.1 only, to not change behavior
fi
# echo "Analyzed: SERVER_TO_START=$SERVER_TO_START"
if [ ! -d $mysql_datadir/mysql ] ; then
mkdir $mysql_datadir/mysql;
echo "MySQL RPM installation of version $NEW_VERSION" >> $STATUS_FILE
else
# If the directory exists, we may assume it is an upgrade.
echo "MySQL RPM upgrade to version $NEW_VERSION" >> $STATUS_FILE
fi
if [ ! -d $mysql_datadir/test ] ; then mkdir $mysql_datadir/test; fi if [ ! -d $mysql_datadir/test ] ; then mkdir $mysql_datadir/test; fi
# ---------------------------------------------------------------------- # ----------------------------------------------------------------------
# Make MySQL start/shutdown automatically when the machine does it. # Make MySQL start/shutdown automatically when the machine does it.
# ---------------------------------------------------------------------- # ----------------------------------------------------------------------
# NOTE: This still needs to be debated. Should we check whether these links
# for the other run levels exist(ed) before the upgrade?
# use insserv for older SuSE Linux versions # use insserv for older SuSE Linux versions
if [ -x /sbin/insserv ] ; then if [ -x /sbin/insserv ] ; then
/sbin/insserv %{_sysconfdir}/init.d/mysql /sbin/insserv %{_sysconfdir}/init.d/mysql
...@@ -741,11 +825,14 @@ chown -R %{mysqld_user}:%{mysqld_group} $mysql_datadir ...@@ -741,11 +825,14 @@ chown -R %{mysqld_user}:%{mysqld_group} $mysql_datadir
# ---------------------------------------------------------------------- # ----------------------------------------------------------------------
chmod -R og-rw $mysql_datadir/mysql chmod -R og-rw $mysql_datadir/mysql
# Restart in the same way that mysqld will be started normally. # Was the server running before the upgrade? If so, restart the new one.
%{_sysconfdir}/init.d/mysql start if [ "$SERVER_TO_START" = "true" ] ; then
# Restart in the same way that mysqld will be started normally.
%{_sysconfdir}/init.d/mysql start
# Allow mysqld_safe to start mysqld and print a message before we exit # Allow mysqld_safe to start mysqld and print a message before we exit
sleep 2 sleep 2
fi
#echo "Thank you for installing the MySQL Community Server! For Production #echo "Thank you for installing the MySQL Community Server! For Production
#systems, we recommend MySQL Enterprise, which contains enterprise-ready #systems, we recommend MySQL Enterprise, which contains enterprise-ready
...@@ -753,6 +840,14 @@ sleep 2 ...@@ -753,6 +840,14 @@ sleep 2
#scheduled service packs and more. Visit www.mysql.com/enterprise for more #scheduled service packs and more. Visit www.mysql.com/enterprise for more
#information." #information."
# Collect an upgrade history ...
echo "Upgrade/install finished at `date`" >> $STATUS_FILE
echo >> $STATUS_FILE
echo "=====" >> $STATUS_FILE
STATUS_HISTORY=$mysql_datadir/RPM_UPGRADE_HISTORY
cat $STATUS_FILE >> $STATUS_HISTORY
rm $STATUS_FILE
%if %{CLUSTER_BUILD} %if %{CLUSTER_BUILD}
%post ndb-storage %post ndb-storage
mysql_clusterdir=/var/lib/mysql-cluster mysql_clusterdir=/var/lib/mysql-cluster
...@@ -1038,6 +1133,17 @@ fi ...@@ -1038,6 +1133,17 @@ fi
# merging BK trees) # merging BK trees)
############################################################################## ##############################################################################
%changelog %changelog
* Tue Jun 15 2010 Joerg Bruehe <joerg.bruehe@sun.com>
- Change the behaviour on upgrade:
*Iff* the server was stopped before the upgrade is started, this is taken as a
sign the administrator is handling that manually, and so the new server will
not be started automatically at the end of the upgrade.
The start/stop scripts will still be installed, so the server will be started
on the next machine boot.
This is the 5.1 version of fixing bug#27072 (RPM autostarting the server).
* Mon Mar 01 2010 Joerg Bruehe <joerg.bruehe@sun.com> * Mon Mar 01 2010 Joerg Bruehe <joerg.bruehe@sun.com>
- Set "Oracle and/or its affiliates" as the vendor and copyright owner, - Set "Oracle and/or its affiliates" as the vendor and copyright owner,
......