MDEV-23843 Assertions in Diagnostics_area upon table operations under FTWRL
2 different problems: - MYSQL_BIN_LOG::write() did not check if mdl_context.acquire_lock() failed - Sql_cmd_optimize_table::execute() and Sql_cmd_repair_table::execute() called write_bin_log(), which could fail if sql_admin() had already called my_eof() Fixed by adding check for aquire_lock() return status and protect write_bin_log() in the above two functions with set_overwrite_status().