- 14 Feb, 2010 1 commit
-
-
Alexander Nozdrin authored
-
- 12 Feb, 2010 7 commits
-
-
unknown authored
-
Joerg Bruehe authored
-
Joerg Bruehe authored
-
Joerg Bruehe authored
-
Joerg Bruehe authored
no other functional changes.
-
Evgeny Potemkin authored
function with distinct. Loose index scan is used to find MIN/MAX values using appropriate index and thus allow to avoid grouping. For each found row it updates non-aggregated fields with values from row with found MIN/MAX value. Without loose index scan non-aggregated fields are copied by end_send_group function. With loose index scan there is no need in end_send_group and end_send is used instead. Non-aggregated fields still need to be copied and this was wrongly implemented in QUICK_GROUP_MIN_MAX_SELECT::get_next. WL#3220 added a case when loose index scan can be used with end_send_group to optimize calculation of aggregate functions with distinct. In this case the row found by QUICK_GROUP_MIN_MAX_SELECT::get_next might belong to a next group and copying it will produce wrong result. Update of non-aggregated fields is moved to the end_send function from QUICK_GROUP_MIN_MAX_SELECT::get_next. mysql-test/r/group_min_max.result: Added a test case for the bug#50539. mysql-test/t/group_min_max.test: Added a test case for the bug#50539. sql/opt_range.cc: Bug#50539: Wrong result when loose index scan is used for an aggregate function with distinct. Update of non-aggregated fields is moved to the end_send function from QUICK_GROUP_MIN_MAX_SELECT::get_next. sql/sql_select.cc: Bug#50539: Wrong result when loose index scan is used for an aggregate function with distinct. Update of non-aggregated fields is moved to the end_send function from QUICK_GROUP_MIN_MAX_SELECT::get_next.
-
unknown authored
--slave-load-tm The MDL_SHARED lock was introduced for an object in 5.4, but the 'TABLE_LIST' object was not initialized with the MDL_SHARED lock when applying event with LOAD DATA INFILE into table. So the failure is caused when checking the MDL_SHARED lock for the object. To fix the problem, the 'TABLE_LIST' object was initialized with the MDL_SHARED lock when applying event with LOAD DATA INFILE into table. mysql-test/suite/rpl/t/disabled.def: Got rid of the line for enabling 'rpl_cross_version' test.
-
- 11 Feb, 2010 3 commits
-
-
Joerg Bruehe authored
this includes a major whitespace (formatting) alignment and sequence changes to better agree with other spec files. Further changes: - All features are controlled by "%define" set from call options or builtin. - "bundled zlib" is on by default. - "with libgcc" is controlled by runtime detection of gcc. - Handling of "CFLAGS" and "CXXFLAGS" is more concentrated. - Several missing man pages were added.
-
Magne Mahre authored
causing crashes! Adding a SPATIAL INDEX on a non-geometrical column caused a segmentation fault when the table was subsequently inserted into. A test was added in mysql_prepare_create_table to explicitly check whether non-geometrical columns are used in a spatial index, and throw an error if so. mysql-test/t/gis.test: Added test cases to verify that only geometrical columns can get a spatial index. In addition, verify that only a single geom. column can participate in a spatial index.
-
Magne Mahre authored
corruption and crash results An index creation statement where the index key is larger/wider than the column it references should throw an error. A statement like: CREATE TABLE t1 (a CHAR(1), PRIMARY KEY (A(255))) did not error, but a segmentation fault followed when an insertion was attempted on the table The partial key validiation clause has been restructured to (hopefully) better document which uses of partial keys are valid.
-
- 10 Feb, 2010 2 commits
-
-
Luis Soares authored
We found that there are some tests that are not cleaning up properly: 1. rpl_tmp_table_and_DDL 2. rpl_do_grant 3. rpl_sync For #1 and #2 we found that the slave would not, for some cases, replicate all the instructions the master processed in the cleanup section. We fix these by deploying some synchronization commands in the test cases so that slave processes all clean up instructions. As for #3, this is tracked as part of another bug (BUG@50442).
-
Mattias Jonsson authored
Problem was that in mysql-trunk the ER() macro is now dependent on current_thd and the innodb monitor thread has no binding to that thd object. This cause the crash because of bad derefencing. Solution was to add a new macro which take the thd as an argument (which the innodb thread uses for the call). (Updated according to reviewers comments, i.e. added ER_THD_OR_DEFAULT and moved test to suite parts.) mysql-test/suite/parts/r/partition_innodb_status_file.result: Bug#50201: Server crashes in explain_filename on an InnoDB partitioned table New test result file mysql-test/suite/parts/t/partition_innodb_status_file-master.opt: Bug#50201: Server crashes in explain_filename on an InnoDB partitioned table New test opt file mysql-test/suite/parts/t/partition_innodb_status_file.test: Bug#50201: Server crashes in explain_filename on an InnoDB partitioned table New test. Note that the innodb monitor thread only runs every 15 seconds, so this test will take at least 15 seconds, so I have moved it to the parts suite. sql/sql_table.cc: Bug#50201: Server crashes in explain_filename on an InnoDB partitioned table Using thd safe ER macro. sql/unireg.h: Bug#50201: Server crashes in explain_filename on an InnoDB partitioned table Added ER macros for use with specified thd pointer.
-
- 09 Feb, 2010 2 commits
-
-
Alexander Nozdrin authored
-
Alexander Nozdrin authored
-
- 08 Feb, 2010 3 commits
-
-
Joerg Bruehe authored
fixing bug#50950.
-
Joerg Bruehe authored
fixing bug#50950.
-
Joerg Bruehe authored
in message printed at end of configure New text for the success message of "configure". configure.in: The message must be changed to drop the "www.mysql.com" URL.
-
- 05 Feb, 2010 4 commits
-
-
Alexander Nozdrin authored
-
Alexander Nozdrin authored
Original revision: ------------------------------------------------------------ revision-id: kent.boortz@sun.com-20100204182709-dw1dwpglkd5qrehb committer: Kent Boortz <kent.boortz@sun.com> branch nick: mysql-5.1-bugteam timestamp: Thu 2010-02-04 19:27:09 +0100 message: LT_INIT and LT_PREREQ was added in libtool 2.2 2008, a bit too recent, switched back to the older AC_PROG_LIBTOOL ------------------------------------------------------------
-
Alexander Nozdrin authored
-
Alexander Nozdrin authored
-
- 04 Feb, 2010 6 commits
-
-
unknown authored
-
Georgi Kodinov authored
-
Georgi Kodinov authored
-
He Zhenxing authored
-
He Zhenxing authored
-
He Zhenxing authored
The number for MYSQL_REPLICATION_PLUGIN was shifted when backporting because MYSQL_AUDIT_PLUGIN was not backported. This problem is fixed by backporting only the number of audit plugin and print an error when trying to load audit plugins. Note that replication plugins compiled against old MYSQL_REPLICATION_PLUGIN number will also be recognized as audit plugin and be rejected. include/mysql/plugin.h: backporting the number of audit plugin (MYSQL_AUDIT_PLUGIN) sql/sql_plugin.cc: backporting the number of audit plugin (MYSQL_AUDIT_PLUGIN) print an error when trying to load audit plugins
-
- 03 Feb, 2010 9 commits
-
-
Alexander Nozdrin authored
Conflicts: - configure.in - mysql-test/include/setup_fake_relay_log.inc - sql/sql_select.cc
-
Luis Soares authored
fails in PB sporadically) The IO thread can concurrently access the relay log IO_CACHE while another thread is performing an FLUSH LOGS procedure. FLUSH LOGS closes and reopens the relay log and while doing so it (re)initializes its IO_CACHE. During this procedure the IO_CACHE mutex is also reinitialized, which can cause problems if some other thread (namely the IO THREAD) is concurrently accessing it at the time . This patch fixes the problem by extending the interface of the flush_master_info function to also include a second paramater, "need_relay_log_lock", stating whether the thread should grab the relay log lock or not before actually flushing the relay log. Also, IO thread now calls flush_master_info with this flag set when it flushes master info with in the event read_event loop. Finally, we also increase loop time in rpl_heartbeat_basic test case, so that the number of calls to flush logs doubles, stressing this part of the code a little more. mysql-test/suite/rpl/t/rpl_heartbeat_basic.test: Doubled the number of iterations on the FLUSH LOGS loop by doubling the time available to perform all iterations. sql/repl_failsafe.cc: Updating flush_master_info call so that it uses two parameters instead of one. sql/rpl_mi.cc: Updating flush_master_info call so that it uses two parameters instead of one. sql/rpl_mi.h: Changed flush_master_info interface. Now takes a second parameter instead of just one. The second parameter is: need_lock_relay_log. sql/rpl_rli.cc: Small fix in comment. sql/slave.cc: Updating flush_master_info call so that it uses two parameters instead of one. sql/sql_repl.cc: Updating flush_master_info call so that it uses two parameters instead of one.
-
Alexander Nozdrin authored
Conflicts: - sql/mysqld.cc
-
Georgi Kodinov authored
-
Georgi Kodinov authored
-
Georgi Kodinov authored
-
Alexander Nozdrin authored
Conflicts: - mysql-test/collections/default.experimental - mysql-test/suite/rpl/r/rpl_sp.result
-
Kent Boortz authored
-
Luis Soares authored
-
- 02 Feb, 2010 3 commits
-
-
Kent Boortz authored
path names than 99 characters, using the USTAR format of the resulting source TAR. To be able to specify the use of USTAR when creating the source TAR, we needed both to update the GNU autotools version requirements slightly, and update the initiation of the tools to use more modern constructs.
-
Joerg Bruehe authored
Get rid of trailing blanks.
-
Magne Mahre authored
--default-character-set and --character-set-server such that only the first will give a deprecation warning. Apart from that, the two options should do the same.
-