- 31 Mar, 2007 2 commits
-
-
tomas@whalegate.ndb.mysql.com authored
into whalegate.ndb.mysql.com:/home/tomas/mysql-5.1-single-user
-
ibabaev@bk-internal.mysql.com authored
into bk-internal.mysql.com:/data0/bk/mysql-5.0-opt
-
- 30 Mar, 2007 14 commits
-
-
sergefp@pylon.mylan authored
into mysql.com:/home/psergey/mysql-5.1-merge2
-
evgen@moonbone.local authored
After merge fix.
-
evgen@moonbone.local authored
into moonbone.local:/mnt/gentoo64/work/bk-trees/mysql-5.1-opt
-
sergefp@mysql.com authored
-
sergefp@mysql.com authored
Pushbuild fixes: - Make MAX_SEL_ARGS smaller (even 16K records_in_range() calls is more than it makes sense to do in typical cases) - Don't call sel_arg->test_use_count() if we've already allocated more than MAX_SEL_ARGs elements. The test will succeed but will take too much time for the test suite (and not provide much value).
-
ibabaev@bk-internal.mysql.com authored
into bk-internal.mysql.com:/data0/bk/mysql-5.1-opt
-
evgen@sunlight.local authored
NO_AUTO_VALUE_ON_ZERO mode. In the NO_AUTO_VALUE_ON_ZERO mode the table->auto_increment_field_not_null variable is used to indicate that a non-NULL value was specified by the user for an auto_increment column. When an INSERT .. ON DUPLICATE updates the auto_increment field this variable is set to true and stays unchanged for the next insert operation. This makes the next inserted row sometimes wrongly have 0 as the value of the auto_increment field. Now the fill_record() function resets the table->auto_increment_field_not_null variable before filling the record. The table->auto_increment_field_not_null variable is also reset by the open_table() function for a case if we missed some auto_increment_field_not_null handling bug. Now the table->auto_increment_field_not_null is reset at the end of the mysql_load() function. Reset the table->auto_increment_field_not_null variable after each write_row() call in the copy_data_between_tables() function.
-
istruewing@chilla.local authored
into chilla.local:/home/mydev/mysql-5.1-axmrg
-
istruewing@chilla.local authored
into chilla.local:/home/mydev/mysql-5.1-axmrg
-
tomas@whalegate.ndb.mysql.com authored
-
istruewing@chilla.local authored
into chilla.local:/home/mydev/mysql-5.0-axmrg
-
istruewing@chilla.local authored
-
istruewing@chilla.local authored
into chilla.local:/home/mydev/mysql-5.1-axmrg
-
istruewing@chilla.local authored
into chilla.local:/home/mydev/mysql-5.1-axmrg
-
- 29 Mar, 2007 24 commits
-
-
istruewing@chilla.local authored
into chilla.local:/home/mydev/mysql-5.1-axmrg
-
istruewing@chilla.local authored
into chilla.local:/home/mydev/mysql-5.0-axmrg
-
svoj@april.(none) authored
into mysql.com:/home/svoj/devel/mysql/BUG25521/mysql-5.1-engines
-
tomas@whalegate.ndb.mysql.com authored
into whalegate.ndb.mysql.com:/home/tomas/mysql-5.1-single-user
-
svoj@mysql.com/april.(none) authored
into mysql.com:/home/svoj/devel/mysql/BUG25521/mysql-5.0-engines
-
tomas@whalegate.ndb.mysql.com authored
- do not try to perge binlog when purge comes from slave, it never purges binlog anyways
-
gkodinov/kgeorge@magare.gmz authored
into magare.gmz:/home/kgeorge/mysql/autopush/B26815-5.0-opt
-
gkodinov/kgeorge@magare.gmz authored
into magare.gmz:/home/kgeorge/mysql/autopush/B26815-5.0-opt
-
gkodinov/kgeorge@magare.gmz authored
When creating a temporary table the concise column type of a string expression is decided based on its length: - if its length is under 512 it is stored as either varchar or char. - otherwise it is stored as a BLOB. There is a flag (convert_blob_length) to create_tmp_field that, when >0 allows to force creation of a varchar if the max blob length is under convert_blob_length. However it must be verified that convert_blob_length (settable through a SQL option in some cases) is under the maximum that can be stored in a varchar column. While performing that check for expressions in create_tmp_field_from_item the max length of the blob was used instead. This causes blob columns to be created in the heap temp table used by GROUP_CONCAT (where blobs must not be created in the temp table because of the constant convert_blob_length that is passed to create_tmp_field() ). And since these blob columns are not expected in that place we get wrong results. Fixed by checking that the value of the flag variable is in the limits that fit into VARCHAR instead of the max length of the blob column.
-
istruewing@chilla.local authored
-
tomas@whalegate.ndb.mysql.com authored
into whalegate.ndb.mysql.com:/home/tomas/mysql-5.1-single-user
-
tomas@whalegate.ndb.mysql.com authored
into whalegate.ndb.mysql.com:/home/tomas/mysql-5.0-ndb
-
tomas@whalegate.ndb.mysql.com authored
into whalegate.ndb.mysql.com:/home/tomas/mysql-5.1-single-user
-
tomas@whalegate.ndb.mysql.com authored
into whalegate.ndb.mysql.com:/home/tomas/mysql-5.1-single-user
-
tomas@whalegate.ndb.mysql.com authored
- quick workaround, better patch is needed later - test case
-
tomas@whalegate.ndb.mysql.com authored
into whalegate.ndb.mysql.com:/home/tomas/mysql-5.1-single-user
-
tomas@whalegate.ndb.mysql.com authored
- also run this patch on 32 bit machines to allow online upgrade
-
tomas@whalegate.ndb.mysql.com authored
into whalegate.ndb.mysql.com:/home/tomas/mysql-5.1-single-user
-
sergefp@mysql.com authored
changes made by the bug fix.
-
gkodinov/kgeorge@magare.gmz authored
into magare.gmz:/home/kgeorge/mysql/autopush/B27300-5.0-opt
-
tomas@whalegate.ndb.mysql.com authored
- increase var part reference from 32 to 64 bits on 64 bit systems - note current patch does not allow for online upgrade from 32 to 64 bit systems or vice versa
-
sergefp@pylon.mylan authored
into mysql.com:/home/psergey/mysql-5.1-merge
-
gkodinov/kgeorge@magare.gmz authored
into magare.gmz:/home/kgeorge/mysql/autopush/B27300-5.0-opt
-
joerg@trift-lap.fambruehe authored
into trift-lap.fambruehe:/MySQL/M51/push-5.1
-