Alexander Usyskin authored
The MEI FW can receive only one flow control for read. Currently the driver only checks if a flow control credit was already sent and read is pending in the rd_pending queue, but it also has to check if flow control credit already queued in the write control queue to prevent sending more than one flow control credits. Signed-off-by: Alexander Usyskin <alexander.usyskin@intel.com> Signed-off-by: Tomas Winkler <tomas.winkler@intel.com> Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
13cf9885