Hristo Venev authored
On Kingston KC3000 and Kingston FURY Renegade (both have the same PCI IDs) accessing temp3_{min,max} fails with an invalid field error (note that there is no problem setting the thresholds for temp1). This contradicts the NVM Express Base Specification 2.0b, page 292: The over temperature threshold and under temperature threshold features shall be implemented for all implemented temperature sensors (i.e., all Temperature Sensor fields that report a non-zero value). Define NVME_QUIRK_NO_SECONDARY_TEMP_THRESH that disables the thresholds for all but the composite temperature and set it for this device. Signed-off-by: Hristo Venev <hristo@venev.name> Reviewed-by: Guenter Roeck <linux@roeck-us.net> Signed-off-by: Christoph Hellwig <hch@lst.de>
bd375fee