Johan Hovold authored
When the termios CIBAUD bits are left unset (i.e. B0), we use the same output and input speed and should leave CIBAUD unchanged. When the user requests a rate using BOTHER and c_ospeed which the driver cannot set exactly, the driver can report back the actual baud rate using tty_termios_encode_baud_rate(). If this rate is close enough to a standard rate however, we could end up setting CIBAUD to a Bfoo value despite the user having left it unset. This in turn could lead to an unexpected input rate being set on subsequent termios updates. Fix this by using a zero tolerance value also for the input rate when CIBAUD is clear so that the matching logic works as expected. Fixes: 78137e3b ("[PATCH] tty: improve encode_baud_rate logic") Signed-off-by: Johan Hovold <johan@kernel.org> Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
1cee38f0