Zhang Rui authored
When setting a trip point temperature from sysfs, there is an upper bound check on the user input, but no lower bound check. As hardware register has 7 bits for a trip point temperature, the offset to tj_max of the input temperature must be equal to/less than 0x7f. Or else, 1. bogus temperature is updated into the trip temperature bits. 2. the upper bits of the register can be polluted. For example, $ rdmsr 0x1b2 2000003 $ echo -180000 > /sys/class/thermal/thermal_zone1/trip_point_1_temp $ rdmsr 0x1b2 3980003 Not only the trip point temp is set to 76C on this platform (tj_max is 100), the Power Notification (Bit 24) is also enabled erronously. Fix the problem by adding lower bound check for sysfs input. Reported-by: Dan Carpenter <error27@gmail.com> Link: https://lore.kernel.org/all/add7a378-4d50-4ba1-81d3-a0c17db25a0b@kili.mountain/Signed-off-by: Zhang Rui <rui.zhang@intel.com> Signed-off-by: Rafael J. Wysocki <rafael.j.wysocki@intel.com>