Tung Nguyen authored
[ Upstream commit 36a50a98 ] When configuring the number of used bearers to MAX_BEARER and issuing command "tipc link monitor summary", the command enters infinite loop in user space. This issue happens because function tipc_nl_node_dump_monitor() returns the wrong 'prev_bearer' value when all potential monitors have been scanned. The correct behavior is to always try to scan all monitors until either the netlink message is full, in which case we return the bearer identity of the affected monitor, or we continue through the whole bearer array until we can return MAX_BEARERS. This solution also caters for the case where there may be gaps in the bearer array. Signed-off-by: Tung Nguyen <tung.q.nguyen@dektech.com.au> Signed-off-by: Jon Maloy <jon.maloy@ericsson.com> Signed-off-by: David S. Miller <davem@davemloft.net> Signed-off-by: Sasha Levin <alexander.levin@microsoft.com> Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
3f64c0c5