• Xiang Chen's avatar
    scsi: hisi_sas: Remedy inconsistent PHY down state in software · 447f78c0
    Xiang Chen authored
    Currently there are two scenarioes which may cause PHY state of hardware
    (which is 0) is inconsistent with the state held in software:
    
    - Unplug SAS wire before get_phys_state when SAS controller reset, then the
      interrupts of phy down are ignored, phy state is 0 before reset, and it
      also gets 0 after reset, so phy down doesn't occur even if unplugged SAS
      wire;
    
    - For v3 hw later version, it will close bus when 2 bit ECC error occurs.
      So if unplug SAS wire at that time, interrupts of phy down also not
      occur. So at last it will cause host reset. It also get phy state 0
      before and after reset, the same issue occurs.
    
    To solve it, use hisi_sas_phy_down() directly in rescan topology function.
    Signed-off-by: default avatarXiang Chen <chenxiang66@hisilicon.com>
    Signed-off-by: default avatarJohn Garry <john.garry@huawei.com>
    Signed-off-by: default avatarMartin K. Petersen <martin.petersen@oracle.com>
    447f78c0
hisi_sas_main.c 85.6 KB