AngeloGioacchino Del Regno authored
The AUXADC thermal v1 allows reading temperature range between -20°C to 150°C and any value out of this range is invalid. Add new definitions for MT8173_TEMP_{MIN_MAX} and a new small helper mtk_thermal_temp_is_valid() to check if new readings are in range: if not, we tell to the API that the reading is invalid by returning THERMAL_TEMP_INVALID. It was chosen to introduce the helper function because, even though this temperature range is realistically ok for all, it comes from a downstream kernel driver for version 1, but here we also support v2 and v3 which may may have wider constraints. Signed-off-by: AngeloGioacchino Del Regno <angelogioacchino.delregno@collabora.com> Signed-off-by: Daniel Lezcano <daniel.lezcano@linaro.org> Link: https://lore.kernel.org/r/20230419061146.22246-3-angelogioacchino.delregno@collabora.com
47cbb046