Konrad Knitter authored
Since 4.30 firmware exposes internal thermal sensor reading via admin queue commands. Expose those readouts via hwmon API when supported. Datasheet: Get Sensor Reading Command (Opcode: 0x0632) +--------------------+--------+--------------------+-------------------------+ | Name | Bytes | Value | Remarks | +--------------------+--------+--------------------+-------------------------+ | Flags | 1-0 | | | | Opcode | 2-3 | 0x0632 | Command opcode | | Datalen | 4-5 | 0 | No external buffer. | | Return value | 6-7 | | Return value. | | Cookie High | 8-11 | Cookie | | | Cookie Low | 12-15 | Cookie | | | Sensor | 16 | | 0x00: Internal temp | | | | | 0x01-0xFF: Reserved. | | Format | 17 | Requested response | Only 0x00 is supported. | | | | format | 0x01-0xFF: Reserved. | | Reserved | 18-23 | | | | Data Address high | 24-27 | Response buffer | | | | | address | | | Data Address low | 28-31 | Response buffer | | | | | address | | +--------------------+--------+--------------------+-------------------------+ Get Sensor Reading Response (Opcode: 0x0632) +--------------------+--------+--------------------+-------------------------+ | Name | Bytes | Value | Remarks | +--------------------+--------+--------------------+-------------------------+ | Flags | 1-0 | | | | Opcode | 2-3 | 0x0632 | Command opcode | | Datalen | 4-5 | 0 | No external buffer | | Return value | 6-7 | | Return value. | | | | | EINVAL: Invalid | | | | | parameters | | | | | ENOENT: Unsupported | | | | | sensor | | | | | EIO: Sensor access | | | | | error | | Cookie High | 8-11 | Cookie | | | Cookie Low | 12-15 | Cookie | | | Sensor Reading | 16-23 | | Format of the reading | | | | | is dependent on request | | Data Address high | 24-27 | Response buffer | | | | | address | | | Data Address low | 28-31 | Response buffer | | | | | address | | +--------------------+--------+--------------------+-------------------------+ Sensor Reading for Sensor 0x00 (Internal Chip Temperature): +--------------------+--------+--------------------+-------------------------+ | Name | Bytes | Value | Remarks | +--------------------+--------+--------------------+-------------------------+ | Thermal Sensor | 0 | | Reading in degrees | | reading | | | Celsius. Signed int8 | | Warning High | 1 | | Warning High threshold | | threshold | | | in degrees Celsius. | | | | | Unsigned int8. | | | | | 0xFF when unsupported | | Critical High | 2 | | Critical High threshold | | threshold | | | in degrees Celsius. | | | | | Unsigned int8. | | | | | 0xFF when unsupported | | Fatal High | 3 | | Fatal High threshold | | threshold | | | in degrees Celsius. | | | | | Unsigned int8. | | | | | 0xFF when unsupported | | Reserved | 4-7 | | | +--------------------+--------+--------------------+-------------------------+ Driver provides current reading from HW as well as device specific thresholds for thermal alarm (Warning, Critical, Fatal) events. $ sensors Output ========================================================= ice-pci-b100 Adapter: PCI adapter temp1: +62.0°C (high = +95.0°C, crit = +105.0°C) (emerg = +115.0°C) Tested on Intel Corporation Ethernet Controller E810-C for SFP Co-developed-by: Marcin Domagala <marcinx.domagala@intel.com> Signed-off-by: Marcin Domagala <marcinx.domagala@intel.com> Co-developed-by: Eric Joyner <eric.joyner@intel.com> Signed-off-by: Eric Joyner <eric.joyner@intel.com> Reviewed-by: Marcin Szycik <marcin.szycik@linux.intel.com> Reviewed-by: Przemek Kitszel <przemyslaw.kitszel@intel.com> Signed-off-by: Konrad Knitter <konrad.knitter@intel.com> Tested-by: Pucha Himasekhar Reddy <himasekharx.reddy.pucha@intel.com> (A Contingent worker at Intel) Signed-off-by: Tony Nguyen <anthony.l.nguyen@intel.com> Signed-off-by: Paolo Abeni <pabeni@redhat.com>
4da71a77