    i2c: riic: correctly finish transfers · 5f1c2e6a
    Chris Brandt authored
    commit 71ccea09 upstream.
    
    This fixes the condition where the controller has not fully completed its
    final transfer and leaves the bus and controller in a undesirable state.
    
    At the end of the last transmitted byte, the existing driver would just
    signal for a STOP condition to be transmitted then immediately signal
    completion. However, the full STOP procedure might not have fully taken
    place by the time the runtime PM shuts off the peripheral clock, leaving
    the bus in a suspended state.
    
    Alternatively, the STOP condition on the bus may have completed, but when
    the next transaction is requested by the upper layer, not all the
    necessary register cleanup was finished from the last transfer which made
    the driver return BUS BUSY when it really wasn't.
    
    This patch now makes all transmit and receive transactions wait for the
    STOP condition to fully complete before signaling a completed transaction.
    With this new method, runtime PM no longer seems to be an issue.
    
    Fixes: 310c18a4 ("i2c: riic: add driver")
    Signed-off-by: default avatarChris Brandt <chris.brandt@renesas.com>
    Reviewed-by: default avatarWolfram Sang <wsa+renesas@sang-engineering.com>
    Signed-off-by: default avatarWolfram Sang <wsa@the-dreams.de>